17
User manual
www.connectinglegacy.com
When the cursor “
》
”is point to”Battery Status”
,
press “ENTER” key will enter the page of “Battery Status”
,
As
shown in the figure below
:
4.
Parameter Settings
Screen can not set parameters Baud Rate
:
9600 ,Can not be set.
5.
Key description
SW1----MENU
,
SW2----ENTER
,
SW3----UP
,
SW4----DOWN
,
SW5
----
ESC.
Each item is “
》
”or“--”as a beginning
,
among them“
》
”shows the current cursor position
,
press “UP” or
“DOWN” key can move the cursor position
;
with“
》
”end of the project
,
the content of the said project has
not shown, press “ENTER” key can enter the corresponding page.
Press “ESC” key can be returned at the next higher level directory
;
In any position
,
press” MENU” key can
return to the main menu page.
When BMS inter sleep mode, press any key, can activate the screen.
Inter standby mode , with no keystrokes 1 minutes later, LCD will enter Shutdown mode press any key,screen
can be activ.
WARNING:
(
1
)
Emergency process:
1 .The external device catches fire and explodes:
A: Under the condition of ensuring safety, non-operating personnel immediately move to a safe location;
B: Under the condition of ensuring safety, the operator immediately cut off the external power supply of
the equipment and the internal power supply.
C:Use fire-fighting equipment for fire-fighting treatment (the use of fire-fighting sand, fire-fighting
blankets, fire- fighting water pipes)
D:If you cannot completely extinguish the fire, please call the local fire department for help. E:Keep the
accident site data so that the source of the accident can be traced.
2 .The Pack catches fire and explodes:
A: Under the condition of ensuring safety, non-operating personnel immediately move to a safe location;
B: Under the condition of ensuring safety, the operator immediately cut off the external power supply of
the equipment and the internal power supply.
C:Use fire-fighting equipment for fire-fighting treatment (first the use of fire-fighting sand, fire-fighting
blankets, then fire-fighting water pipes for cool the Pack)
D:If you cannot completely extinguish the fire, please call the local fire department for help. E:Keep the
accident site data so that the source of the accident can be traced.