4
Information regarding the electrical voltage and
frequency being supplied to the merchandiser can
be found on the merchandiser’s serial data plate
typically located at the upper left corner of the
merchandiser’s interior. Information regarding the
maximum fuse/circuit breaker size required for the
specific model is available from the condensing unit
data plate.
Condensate Evaporator:
Indoor auto-defrost
models are supplied with a condensate evaporator
heater assembly which is packaged with instructions
and shipped inside the freezer. It will require simple
installation by the consumer (see
Figure 1
). A
separate copy of this instruction sheet is supplied
with the condensate evaporator assembly. The
condensate evaporator assembly contains a drip pan
to collect water generated by the freezer’s defrost
cycle and a heat element to evaporate the water.
Once energized, the heat element in the condensate
evaporator assembly is continuously generating
heat. The freezer is to be placed so that there is at
least 1 inch of air space between the back surface of
the condensate evaporator housing and any wall
surface behind the cabinet which allows for heat
dissipation away from the surface of the wall. The
main power cord should also be routed to avoid
pinching.
Note:
Do not operate an indoor auto-defrost
merchandiser without having a condensate
evaporator assembly installed under the evaporator
drain tube exiting the back wall of the cabinet.
Failure to install this assembly will result in water
draining directly onto the floor during the defrost
cycle. This may result in water damage to the floor
and create a hazardous slip condition in the area
surrounding the freezer.
Figure 1: Condensate Evaporator Installation
Operation
Electronic Controls: Digital Display:
Operating Mode Display:
•
Snowflake “ON” – compressor enabled in
run cycle; control displays current cabinet
temperature.
•
Snowflake “Flashing” – anti short cycle
delay enabled to protect the compressor
from trying to start too frequently.
•
Melting Snowflake “ON” – defrost in
progress, control displays the letters “DE”
•
To view the control’s programmed “Set
Point” (cut-out temperature): press and
release the “Set Key.”
Manual
Defrost
Key
Defrost Enabled
Icon –
Melting
Snowflake
Compressor
Enabled Icon –
Snowflake
Set
Key
Temperature &
Settings
Display