3
Hold the key for 5s to reset the sensor, after reset, Multi-Sensor will send “Device_Reset_Locally”
to the main controller and exclude from the Z-Wave network when the Button is released, this
procedure will reset the Sensor to factory default.
Short press button for 3 times then the sensor sending wake up notification to gateway,
wake up for 10 seconds.
②
LED Indicator: if sensor has not been added to controller, the LED will blink for 5 seconds. The LED will
keep on 3 seconds when joined to controller successfully.
3.
Specification
Model Name
7A-SS-AABC-H0
Detection Technology
PIR
(
Passive Infrared
)
Detection Angle
110°±10° with 2.5m mounting height
Detection Distance
5 meters
Temperature Accuracy
±1
℃
Humidity Accuracy
±5%
Communication Protocol
Z-Wave
Radio Frequency
908.42MHz (US)
868.42MHz(EU), 868.40MHz,868.42MHz, 869.85MHz
921.42MHz (AU)
Maximum Effective Radiated Power
≤
0 dBm
Wireless Range
More than 70m outdoors
About 30m indoors (depending
on building materials)
Power Source
CR123A 3VDC battery or Micro USB(reserved)
Battery Life
2 years
Mounting
Screws or 3M Tape
Mounting Height
7.22 ft to 9.19 ft (2.2m to 2.8m)
,
recommend 2.5 meters
Mounting Location
Wall Surface
Operating Temperature
-10°C to + 45°C
Operating Humidity
10%RH to 90%RH
Certifications
CE/FCC,Z-Wave
Dimensions (mm)
51(L)X51(W)X67.5(H)
OTA
Yes