STRATOS STROBE
CONTROL OPTIONS
Set the start address using the group of dip switches located usually on the back of the fixture.
Each dipswitch has an associated value. Adding the value of each switch in the ON position will
provide the start address. Determining which switches to toggle ON given a specific start address
can be accomplished in the following manner. By subtracting the largest switch value possible
from the selected start address until zero is achieved.
on
on
EXAMPLE STARTING ADDRESS
Address 10
Pin NO: 4 = 8
Pin NO: 2 = 2
Total = 10
Address 24
Pin NO: 5 = 16
Pin NO: 4 = 8
Total = 24
DMX address using
simple maths
233 - (128 = 105, Turn on dip No: 8
105 - (64) = 41, Turn on dip No:7
41 - (32) = 9, Turn on dip No: 6
9 - (8) = 1, Turn on dip No: 4
1 - (1) = 0, Turn on dip No:1
You will most likely use the first available
number which maybe Number 1. This
number was selected for
example purposes
DIP SWITCH
(DMX VALUE)
1
2
3
4
5
6
7
8
9
10
1
2
4
8
16
32
64
128
256