1
2
Artnet-DMX converter is the Ethernet Control System based on the Artnet protocol, used to convert the Artnet network data
package into DMX512 data, adopting high-speed ARM processor, stable and reliable working. Following Artnet standard
protocol, it supports RJ45 network interface and standard DMX512 output interface.
Artnet-DMX-8 use standard 1U(19" ) chassis architecture, convenient installation in professional cabinet, easily operation
setting with LCD display.
Artnet-DMX-8 provides 8 standard DMX512 data output port, total output 8×512 data.
It is compatible with all the effects lighting control software which support Art-net protocol, widely used in the LED dot matrix
and the stage lighting control network in needing lots of DMX-512 data, especially for TV station recorded scene, stage
performances, entertainment and so on.
44mm
1. Based on Artnet protocol network data communication, accept network DMX data.
2. Two different IP address for each controller
3. Send packets to the network by broadcast mode
4. Manage Artnet on broadcast mode or unicast mode
5. Standard 1U(19" ) chassis architecture, convenient installation in the standard cabinet.
6. With LCD screen display, convenient operation intuitive settings
7. Provides 8 standard DMX512 data output port,output 8×512 data in total.
8. Set different network segments to avoid multiple sets Artnet data interference.
9. Compatible with the light software based on Artnet Protocol, control stage lighting and LED lighting simultaneously.
Artnet-DMX-8
DMX512
AC100-240V (with a power adaptor)
L482.6×W200×H44mm
L550×W265×H100mm
2200g
-20
~65
℃
℃
Artnet
8 512
×
channels
440m
m
200mm
482
.6m
m
1
2
3
PUSH
DMX 8
Ethernet
DC12V
1
2
3
PUSH
DMX 7
1
2
3
PUSH
DMX 6
1
2
3
PUSH
DMX 5
1
2
3
PUSH
DMX 4
1
2
3
PUSH
DMX 3
1
2
3
PUSH
DMX 2
1
2
3
PUSH
DMX 1
Artnet-DMX-8
WELCOME
DMX
output1-8
Artnet input
Power input
OFF
/
ON
Menu button
(
Exit button
)
Set button
(Save button)
LCD Monitor -Button
+
Button
Status lamp
(
there will be flicker when data transfer
)
Back
Front
One IP manage 1 Subnet and 4 Universe addresses, that is one IP manage 4 output ports
(see the below table)
The calculation method of DMX group address: Group address=Subnet*16 + Universe
:
For example: Subnet for Node 1 is 2, Outlet: Univ for 2 is 8, then Outlet: the group address of 2 is Address=2*16+8=40
IP
Subnet(0~15)
Universe
(0~15)
remark: Two IP address can not be set to the same value to avoid the controller is not working properly caused by IP conflict.
Node 1 IP
2 . 0 . 0 . 2
Node 1 IP
2 . 0 . 0 . 3
Node 1
Subnet:
0
Node 2
Subnet:
0
Outlet : 1
Univ:
0
Outlet : 5
Univ:
4
Outlet : 2
Univ:
1
Outlet : 6
Univ:
5
Outlet : 3
Univ:
2
Outlet : 7
Univ:
6
Outlet : 4
Univ:
3
Outlet : 8
Univ:
7
Other Functions of Button:
Main
interface
Press the menu button in the main interface to enter the menu interface(see the below table).
Press the +/- button / to move up and down the menu and set the relative parameter through press the setting
button . Press the +/- button / can increase or decrease the parameter. Press the setting button to
save the setting when finished and press the menu button to quit the setting status.
Button Operating Instructions:
1. Technical Specs
2. Performance Features
Output signal
Power input
Working temperature
Dimension
Package Size
Weight (G.W)
Input signal
DMX channels
3. Product dimension
4. Interface instruction
In the main interface, long press the setting button to enter test mode (send the dark, light and
highlighting skipping data changing effect to the 8 ports). Press the menu button or setting button to quit the
test mode.In the main interface, long press the +/- button / at the same time to restore factory settings.
Test Mode
warranty
5 years
Контроллер LT-Artnet-DMX-8
(220V, 4096CH)