23
Reference Manual for Operation
Rio Rancho, NM – USA
TopMenu - SysInfo
Navigate to the the SysInfo item on the Top Menu. Press the encoder
knob to access the information screen.
System Information Screen
This screen provides the basic information about the unit and its present
state in the system. The firmware revision is shown at the top and serial
number on the second line.
The Active Preset is shown on the third line. Keep in mind that this is
the last preset recalled, and that changes to the configuration may have
been made after it was recalled.
The bottom line shows the units position in the chain when multiple units
are stacked.
System Information
General Settings
Setup - General
Navigate to this item on the Setup menu and press the encoder knob to
enter the General Setup screen.select the mode.
General Setup - Mode
Select M/S and rotate the encoder knob to select MASTER or SLAVE.
Then turn the power off and back on again to reset the mode. The
selected mode will then be stored as the default at power up.
After cycling the power, return to the SysInfo screen and check the
status of the unit (see System Information Screen above). A stand-
alone unit must be set to the MASTER mode and will present itself as
"Unit: 01 of 01" on the SysInfo screen. If a unit is set to SLAVE, but is
running by itself or not connected to a Master unit, an error message will
appear at power up stating that no Master is detected.
Stacking Multiple Units
When two or more units are stacked together, they must be
configured with one unit as MASTER and the others as SLAVE.
Using the procedures and screens shown above, adjust the
mode on each unit for this configuration. Be sure to cycle the
power off and back on to reset the mode as default.
In this example, three units are stacked, with the MASTER on
top and two SLAVE units below it. The MASTER unit presents
itself as "01 of 03," as shown in the upper screen. The two slave
units present themselves with subsequent position numbers in
the stack..
The SysInfo screen is used to verify the correct installation and
wiring of multiple units. At power up, slave units will wait for a
sync signal from the master and then position themselves in
order below the master. Miswiring of the expansion cables, a
bad connection, etc. will produce an error message on one or
more screens.