LeCroy Corporation
Using the Software
36
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
Limitations
Simulation Mode lets you try all of the available functions, but the system
is not capturing any real data and is displaying only
pre
‐
captured results.
Using the Software
The Sierra M6
‐
2 application has the LeCroy SAS Protocol Suite and the
LeCroy SATA Protocol Suite.
The LeCroy SAS Protocol Suite can be a:
Protocol
Analyzer:
Captures data, triggers on events, and saves.
Easy
Mode
allows standard Trigger and Data capture.
Advanced
Mode
(requires license)
allows you to program custom triggering in and out, capturing, state jumps, and
timers (
See “Protocol Analysis” on page 41
).
Protocol
Analyzer
Initiator
Emulator:
Generates bus traffic for capture. It also
has Easy Mode and Advanced Mode (
See “Exercise and Capture” on page 109
Target
Emulator
: Acts as target (
See “Target and Device Emulation” on
).
The LeCroy SATA Protocol Suite can be a:
Protocol
Analyzer:
Captures data, triggers on events, and saves.
Easy
Mode
allows standard Trigger and Data capture.
Advanced
Mode
(requires license)
allows you to program custom triggering in and out, capturing, state jumps, and
timers (
See “Protocol Analysis” on page 41
).
Protocol
Analyzer
Host
Emulator:
Generates bus traffic for capture. It also has
Easy Mode and Advanced Mode (
See “Exercise and Capture” on page 109
Device
Emulator
: Acts as device (
See “Target and Device Emulation” on
).
Protocol Analyzer
To use the software for protocol analysis, first select
File
>
New
>
Protocol
Analyzer
for a
new project or
File
>
Open
an existing protocol analysis file: .
sac
for a SAS file or .
stc
for a
SATA file (
See “Protocol Analysis” on page 41
). You can also open a
.scs
SAS Sample file or
.sts
SATA Sample file. Example files are in the Examples folder. You can also use
Project
Setup
>
Last
Protocol
Analyzer.
On the Capture tab, select to capture
Everything
or
Pattern
. For Pattern, select a Pattern.
You can exclude patterns and frames. You can use different patterns for pre
‐
trigger and
post
‐
trigger.
On the Trigger tab, select the trigger type. For Pattern, select the pattern.
On the Settings tab, select trigger position and memory use.
Change the Analyzer settings if necessary. Change the port Speed if necessary.
Use Advanced Mode only after you become familiar with the hardware and software and
have special needs.
Содержание Sierra M6-2
Страница 18: ...LeCroy Corporation Contents 16 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 42: ...LeCroy Corporation Viewing Captured Data 40 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 192: ...LeCroy Corporation Target and Device Emulation 190 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 241: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 239 Search LeCroy Corporation Figure 3 64 SAS Search Data Pattern ...
Страница 314: ...LeCroy Corporation Running Verification Script Engine VSE 312 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 462: ...LeCroy Corporation Resetting the Toolbar 460 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 468: ...LeCroy Corporation 466 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...