LS600 Installation and Operation Guide
17
www.leadsolarenergy.com
LeadSolar Microinverter System Operation Guide
Congratulations on finishing the PV system installation! Follow these steps to begin operation:
1. Close the AC circuit breaker for each branch circuit (usually 18A rating breakers).
2. Close the main circuit breaker for the entire system. This breaker should be chosen based on your PV
system capacity. The microinverter system will begin operation in about 2 minutes.
3. Plug the Ethernet cable into the Ethernet port on the Link, and the other end of the cable into a spare
port on the broadband router. Place the Link so that its AC cord can reach this outlet. Try unplugging
any other device that may be sharing the outlet with the Link,
4. The Link must be obtain a DHCP (Dynamic Host Configuration Protocol) IP address and have a path to
the internet after power on. And then the Link will
query the data of the microinverters that registered in
our website.
5. Login to your user account onreal-time.
Please note that for the first time power up after installation; the system may need ~10 minutes to establish
communication between each microinverter and LeadSolar Link Gateway. This portal will display the power
generated by each microinverter, along with fault reports for quick trouble shooting.
The basic operation status of each microinverter is also displayed by the indicator LEDs on each
microinverter. It is recommended to take a quick check of the LEDs after initial power up. Each microinverter
will self-check its connection after being connected to DC Power. The Status LED will blink green ten times to
indicate continued connection. A solid red status indicates disconnection -- make sure all plugs are fully
connected.
The table below summarizes the description of the LED indicators’ operation after self-checking:
LED Status
Descriptions
Solid Green
Producing power normally
Flash Green 1s/times
Producing power normally but detecting GFDI error.
Flash Green 2s/times
Standby