User Manual Of EL7-EC** AC Servo
244
Continuous trigger, rising and falling edge = valid
(
ii
)
After activation, trigger signal selection, triggering signal edge settings, counter will
be reset and 0x60B9 status will change as well.
(
iii
)
Probe signal level is shown in 60FD: EXT1 -> bit 26, EXT2 -> bit 27.
Related Objects
Index
Sub
Index
Label
Access
Data
Type
Units
Range
Default
2007h
00h
Probe 1 polarity setting
RW
Uint16
0~0xFFFF
1
2007h
01h
Probe 2 polarity setting
RW
Uint16
0~0xFFFF
1
60B8h
00h
Probe control word
RW
Uint16
0~65535
0
60B9h
00h
Probe status word
RO
Uint16
0~65535
0
60BAh
00h
Probe 1or Z-signal rising
edge latching position
RO
int32
Command
unit
-2147483648~
2147483647
0
60BBh
00h
Probe 1 or Z-signal falling
edge latching position
RO
int32
Command
unit
-2147483648~
2147483647
0
60BCh
00h
Probe 2 or Z-signal rising
edge latching position
RO
int32
Command
unit
-2147483648~
2147483647
0
60BDh
00h
Probe 2 or Z-signal falling
edge latching position
RO
int32
Command
unit
-2147483648~
2147483647
0
60D5h
00h
Probe 1 or Z-signal rising
edge counter
RO
Uint32
0~4294967296
0
60D6h
00h
Probe 1 or Z-signal falling
edge counter
RO
Uint32
0~4294967296
0
60D7h
00h
Probe 2 or Z-signal rising
edge counter
RO
Uint32
0~4294967296
0
60D8h
00h
Probe 2 or Z-signal falling
edge counter
RO
Uint32
0~4294967296
0
6.13.2 Signal Input of EXT1 and EXT2
EXT1
:
Pin1 and Pin5 of CN1 terminal
EXT2
:
Pin2 and Pin6 of CN1 terminal
6.13.3 Probe Control Word 60B8h
Bit
Definition
Details
0
Probe 1 enable
0--Disable
1--Enable
1
Probe 1 mode
0--Single trigger mode
1--Continuous trigger mode
2
Probe 1 trigger signal selection 0—EXT1 signal
1--Z signal
3
Reserved
-
4
Probe 1 rising edge trigger
0--Disable
1--Enable