User Manual of EL6-CAN AC Servo
www.leadshine.com
82
Halt = 1: Axis has velocity 0
6.7.3 Related objects
Object Dictionary
Description
Setup value
Units
6060H
Mode of operation
4
6040H
Controlword
6041H
Statusword
6071H
Target torque
0.1%
6087H
Torque change rate
0.1%/s
6080H
Maximum motor speed
r/min
6074H
Torque demand
0.1%
6077H
Torque actual value
0.1%
6.7.4 Example of profile torque mode
No
Command
Function
1
81
00
00 00 00 00 00 00
Reset all nodes. If you need to reset the specified node, the node
number is changed by modifying the two digits after 81 (note that
it is hexadecimal)
2
01
00
00 00 00 00 00 00
Start remote control for all nodes. If remote control of the
specified node needs to be started, the node number is changed by
modifying the two-digit number after 01 (note that it is
hexadecimal).
3
2b
40 60
00 06 00 00 00
Write control word as 06
H
,
state machine switching status
Switch On Disabled->Ready to Switch On
4
2b
40 60
00 07 00 00 00
Read control word as 07H
,
state machine switching status
Ready to Switch On-> Switched On
The relay in the actuator is engaged at this point
5
2b
40 60
00 0f 00 00 00
Write control word as 0fH
,
state machine switching status
Switched On->Operation Enable. Servo-Enabled
6
2f
60 60
00 04 00 00 00
Write operation mode as 4H, profile torque mode
7
23
71 60
00 14 00 00 00
Write the torque value as 14H
(
20*0.1%=1% rated torque
)
8
2b
74 20
00 e8 03 00 00
Write the speed limit (Pr3.21) as 3e8H (1000 RPM)
9
23
87 60
00 14 00 00 00
Write the rate of change in torque as 14H
(
That is, increases to
20*0.1% of the rated torque =2% /s
)
10
2b
40 60
00 07 00 00 00
Write control word as 07H,state machine switching status
Operation Enable -> Switched On. Servo-Disabled
11
2b
40 60
00 06 00 00 00
Write control word as 06H,state machine switching status
Switched On ->Ready to Switch On
Notes: The COB-ID of step 1 (reset node) and step 2 (start node) is "0x000", and the COB-ID of the remaining
steps is the address 0x600 + Node ID