User Manual of EL6-CAN AC Servo
www.leadshine.com
78
6.7.3 Related objects
Object Dictionary
Description
Setup value
Units
6060H
Mode of operation
1
6040H
Controlword
6041H
Statusword
607AH
Target position
Pulse
6081H
Profile velocity
Pulse /s
6083H
Profile acceleration
Pulse /s
2
6084H
Profile deceleration
Pulse /s
2
6092H
Feed constant
6.7.4 Example of profile position mode
No
Command
Function
1
81
00
00 00 00 00 00 00
Reset all nodes. If you need to reset the specified node, the node
number is changed by modifying the two digits after 81 (note that it
is hexadecimal)
2
01
00
00 00 00 00 00 00
Start remote control for all nodes. If remote control of the specified
node needs to be started, the node number is changed by modifying
the two-digit number after 01 (note that it is hexadecimal).
3
2b
40 60
00 06 00 00 00
Write control word as 06
H
,
state machine switching status
Switch On Disabled->Ready to Switch On
4
2b
40 60
00 07 00 00 00
Read control word as 07H
,
state machine switching status
Ready to Switch On-> Switched On
The relay in the actuator is engaged
5
2b
40 60
00 0f 00 00 00
Write control word as 0fH
,
state machine switching status
Switched On->Operation Enable. Servo-Enabled
6
2f
60 60
00 01 00 00 00
Write operation mode as 1H, profile position mode
7
23
81 60
00 90 D0 03 00
Write the protocol speed as 3D090H
(1500rpm, 10000p/r)
8
23
83 60
00 90 D0 03 00
Write the protocol acceleration as 3D090H
(1500rpm/s, 10000p/r)
9
23
7a 60
00 20 4E 00 00
Write the target location at 4E20H
)
10
2b
40 60
00 4f 00 00 00
Write the control word as 4fH
,
Set to relative motion mode
11
2b
40 60
00 5f 00 00 00
Write the control word as 5fH. Execute positioning
12
2b
40 60
00 07 00 00 00
Write control word as 07H,state machine switching status
Operation Enable -> Switched On. Servo-Disabled
13
2b
40 60
00 06 00 00 00
Write control word as 06H,state machine switching status
Switched On ->Ready to Switch On
Notes: The COB-ID of step 1 (reset node) and step 2 (start node) is "0x000", and the COB-ID of the remaining
steps is the address 0x600 + Node ID