User Manual of EL6-CAN AC Servo
www.leadshine.com
70
4. “
Error
” means that writing is unsuccessful
,
while “
Finish
” show that the writing is successful; Follow steps
3 and 4 to repeat the operation; the drive may be damaged if repeat of several times still fails. The drive need
to repair.
5. The drive need to power off and restart again if writing is successful .
NOTE:
D
on’t turn off the power
if EEPROM writing operation goes on, otherwise it may cause a writing wrong
data; If this happens, please reset all the parameters ,then do EEPROM writing operation again.
6.2.5 Abnormal Alarm
The front panel will automatically enter the abnormal alarm display mode if drive error occurs while it
displays the corresponding error code. Please refer to Chapter 6 of alarm processing about the detail of error
code.
Attention
Ground the earth terminal of the motor and drive without fail. the PE terminal of drive must be reliably
connected with the grounding terminal of equipment.
The drive power need with isolation transformer and power filter in order to guarantee the security and
anti-jamming capability.
Check the wiring to make sure correctness before power on.
Install a emergency stop protection circuit externally, the protection can stop running immediately to
prevent accident happened and the power can be cut off immediately.
If drive alarm occurs, the cause of alarm should be excluded and Svon signal must be invalid before
restarting the drive.
Please don’t touch terminal strip or separate the wiring.
Note:
there are two kinds of trial run : trial run without load and trial run with load . The user need to test the
drive without load for safety first.
Contact [email protected] for more technical service .
6.3 Trial Run
6.3.1 Inspection on wiring
Table 6.6 Inspection Item Before Run
No
Item
Content
1
Wiring Inspection
1. Ensure the following terminals are properly wired and securely connected : the
input power terminals, motor output power terminal ,encoder input terminal CN2,
control signal terminal CN1, communication terminal CN3(it is unnecessary to
connect CN1 and CN3 in Jog run mode)
2. short among power input lines and motor output lines are forbidden , and no short
connected with PG ground.
2
Confirmation of
power supply
The range of control power input Vdc, GND must be in the rated range (24-60Vdc).
3
Fixing of position
the motor and drive must be firmly fixed
4
Inspection without
load
the motor shaft must not be with a mechanical load.
5
Inspection on
control signal
1. all of the control switch must be placed in OFF state.
2. servo enable input Srv_on must be in OFF state.
6.3.2 Holding brake
In applications where the motor drives the vertical axis, this brake would be used to hold and prevent the