User Manual of EL6-CAN AC Servo
www.leadshine.com
19
Data Type
16bit
Access
R/W
Address
051FH
Repower
o
I/O input digital filtering; higher setup will arise control delay.
3.3.2 Digital Output Interface
Figure 3-3 Switch Output Interface
(1)
The user provide the external power supply . However, if current polarity connects reversely, servo drive is
damaged.
(2)
The output of the form is open-collector, the maximum voltage is 25V, and maximum current is 50mA.
Therefore, the load of switch output signal must match the requirements. If you exceed the requirements or
output directly connected with the power supply, the servo drive is damaged.
(3)
If the load is inductive loads relays, etc., there must be anti-parallel freewheeling diode across the load. If
the freewheeling diode is connected reversely, the servo drive is damaged.
(4)
Pin7
、
Pin8 and Pin6
:
Single-ended output; Pin9
、
Pin10
:
Differential output.
Pr4.10
Name
Output selection DO1
Mode
F
Range
0~00FFFFFFh
Unit
—
Default
0x81
Index
2410h
Pr4.11
Name
Output selection DO2
Mode
F
Range
0~00FFFFFFh
Unit
—
Default
0x02
Index
2411h
Pr4.12
Name
Output selection DO3
Mode
F
Range
0~00FFFFFFh
Unit
—
Default
0x03
Index
2412h
Assign functions to digital outputs.
This parameter use 16 binary system do setup
For the function number, please refer to the following table.
Signal name
Symbol
Setup Value
Normally open
Normally closed
Master control output
—
00h
Do not setup
Alarm output
Alm
81h
01h
Servo-Ready output
S-RDY
02h
82h
Eternal brake release signal
BRK-OFF
03h
83h
Positioning complete output
INP
04h
84h
At-speed output
AT-SPPED
05h
85h
Torque limit signal output
TLC
06h
86h
Zero speed clamp detection output
ZSP
07h
87h
Velocity coincidence output
V-COIN
08h
88h
Positional command ON/OFF output
P-CMD
0Bh
8Bh
Speed limit signal output
V-LIMIT
0Dh
8Dh
Speed command ON/OFF output
V-CMD
0Fh
8Fh
Servo enable state output
SRV-ST
12h
92h