User Manual of EL6-CAN AC Servo
www.leadshine.com
15
3.1.2 Wiring
Noise Filter
Circuit
Braker
Comtactor
L1
P+
L2
Br
1
POT
4.7K
4.7K
NOT
4.7K
4.7K
12~24Vdc
7
6
8
CN2
U
PE
W
V
2
3
4
5
PE
COM_SI
9
10
N
CN2 Port
Figure 3.1 CANopen Control Mode Wiring
Notes:
1. 4 programmable digital inputs, allows sink input/source input, within the range from 12 VDC to 24 VDC,
30mA
2. 3 programmable digital outputs
(
2 single-ended, 1 differential
)
3.2 Drive Terminals Function
Port
Function
CN1
Pulse + Direction Signal Port
(for EL6-D and EL6-RS version only)
CN2
Digital input/output Port
CN3
Encoder Input Port
CN4
RS232(for configuration software connection)
CANopen
CN5
CANopen
CN6
Encoder output Port(Only for EL6-RS***Z version)
X1
Power Port