iEM-RS Series Modbus RS485 Integrated Stepper Motor
3
2 Specifications
2.1 Electrical and Operating Specifications
Model
Frame
Size
Length
(mm)
Holding
Torque
(N.m)
Weight
(Kg)
Command
Source
Power
Voltage
(VDC)
Peak
Current
(A)
Input
Logical
Voltage
Output
Capability
Max Baud
Rate
Digital
Input
Digital
Output
iEM-RS1706
NEMA
17
73
0.6
1.0
Modbus-RTU
20-36
0.3 - 3.0
12-24V
24V@
100mA
115200
3
1
iEM-RS1708
86
0.8
1.1
20-36
0.3 - 3.0
iEM-RS2313
NEMA
23
78
1.3
1.1
20-50
0.5 - 4.5
iEM-RS2323
99
2.3
1.4
20-50
0.5 - 7.0
2.2 Storage and Installation Conditions
2.2.1 Storage condition
Correctly packaged and store in a clean and dry environment where direct sunlight is avoided.
Store within an ambient temperature ranging from -20
℃
to - +65
℃
(-4 F – 149 F).
Store within a relative humidity ranging from 40% to 90% and non-condensed.
Avoid any type of exposure to corrosive gases.
2.2.2 Operating ambience conditions
Temperature ranging from 0
℃
to 50
℃
. The ambient temperature of drive for long-term reliability should be under 40
℃
.
Please install the drive in a well-ventilated area.
Operation within a relative humidity ranging from 40% to 90% and non-condensed.
Vibration lower than 0.15mm at a frequency of 10Hz-55Hz.
CAUTION
2.3 Dimensions
(unit: mm [1inch=25.4mm])
DO NOT mount the drive and motor in a location subjected to
corrosive or flammable gases, and combustibles.
Please mount the drive and motor in an indoor electric control
cabinet without liquid where direct sunlight is avoided.
DO NOT mount the drive and motor in a location subjected to
airborne dust.
Please ensure grounding wires are securely connected