ASSEMBLY INSTRUCTIONS & PARTS MANUAL FOR

REVERSIBLE CEILING FANS

CEILING FANS SHOULD BE INSTALLED

BY QUALIFIED INSTALLER.

SPECIFICATIONS

MODEL: 5630-1RDP

MODEL

NUMBER

BLADE

SWEEP

COLOR

VOLTAGE

MAX

HZ

MAX
RPM

MAX

AMPS

WATTS

WT

(LBS)

5630-1RDP

56”

White

120

50/60

275

1.0

110

24

READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE OR SERVICE THE LEADING EDGE
CEILING FAN. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

RETAIN FOR FUTURE REFERENCE.

General Safety Information

WARNING: DISCONNECT POWER BEFORE
INSTALLING OR SERVICING THIS EQUIPMENT.

1.  All  electrical  wiring  should  be  done  by  a  qualified

electrician  in  accordance  with  applicable  National
Electrical Code and local electrical codes.

2.  Do  not  allow  moving  blades  to  come  in  contact  with

any part of the body.

3.  Mount  fan  so  that  fan  blades  are  10  feet  or  higher

from floor.

4.  Make  sure  hanger  hooks  are  mounted  securely  to

structural ceiling members.

5.  Do  not  mount  in  an  area  which  will  allow  the  fan  to

get wet.

WARNING: DO NOT USE IN AN EXPLOSIVE
ATMOSPHERE.

6.  Make  certain  that  the  ground  wire  is  connected  to

the  ground  terminal  and  to  a  suitable  electrical
ground.

NOTE: When mounted in cathedral ceilings, the blade tip
should be at least 12 inches from the angled roof line to
prevent air “blow back” causing possible fan sway.

CAUTION: Read and follow instructions carefully.
Failure to comply with instructions could result in
the risk of fire, shock, and injury to persons.

WARNING: TO REDUCE THE RISK OF PERSONAL
INJURY DO NOT BEND THE BLADE BRACKETS
WHEN INSTALLING THE BRACKETS OR CLEANING
THE FAN. DO NOT INSERT FOREIGN OBJECTS IN
BETWEEN ROTATING FAN BLADES.

Description

Leading  Edge  Fans  are  designed  as  a  dual  purpose
product.  By  minimizing  temperature  stratification  in
winter,  they  can  reduce  heating  costs  in  high  bay
buildings. The summertime application provides a gentle
downward  movement  of  air  for  general  air  recirculation
and  evaporative  cooling.  A permanent  split  capacitor
motor  and  permanently  lubricated  ball  bearings  add  to
the efficiency and quietness of the fans.

Unpacking

1. Remove fan components from carton carefully.
2. Check for shipping damage.
3. Check for missing parts against parts list.

RECOMMENDED MOUNTING HEIGHTS

For heat reclamation, this fan should be mounted on the
standard  2’ downrod  included.  On  installations  through
drop ceilings, note the diameter of the downrod hole in
the ceiling should be 2

1

/

2

”.

CAUTION: Fan blades should not be mounted lower
than 10 feet above the floor.