EVG230 NEO.00.ZN03.42.US.0
WARNING:
Do not attempt to start the ventilator if you notice any kind of anomaly.
Contact
Leader North America
immediately.
The following checks must be carried out before first starting the fan:
- Make a visual check of the ventilator
and its accessories to make sure that no damage
occurred during transport.
- If there is any unusual noise, or if the impeller gets stuck, stop the engine and contact
Leader North America
immediately.
- Make sure that everyone responsible for or using this equipment is fully aware of the safety
and operating precautions pertaining to rotating machinery.
INSTRUCTIONS FOR START-UP:
START-UP OPERATIONS:
The way the
EVG230 NEO
fan is started depends on the terrain on which it is being used.
Freely downloadable interactive ventilation courses at
www.leader.educexpert.com
1/
Place the ventilator on a flat surface where there are no slippery products and which is
clear of debris. Make sure there is no obstacle between the fan and the opening for air entry.
2/
Start the fan after making sure that it is in a stable position.
3/
During blowing operations, regularly check that no obstacle is preventing the airflow from
penetrating the interior of the building, or blocking the fan’s suction grill.
USING :
ADJUSTING THE TILT:
Use between 6 and 20 feet from the opening
1) Lift the carrying handle, the fan
is automatically tilted to an angle of
10° (operating angle recommended
for 90% of
incidents).
2)
To close the carrying handle,
unlock it using the index pin (ref. A).
ADJUSTING THE TILT: LANDING, ENTRY WITH STEPS,
OR WINDOW:
Use between 12 and 20 feet from the opening
1)
To adjust the tilt between 10°
and 20°, unlock the tilt adjustment
lever by moving it a quarter turn.
2)
Tilt the fan manually so as to
center the jet on the opening.
3).
Lock the lever while holding the
fan in place so as not to alter the tilt.
EVG230 NEO : GENERAL FEATURES
Manuf
acturer’s reference I63.10.042N
Manufacturer LEADER SAS, Octeville sur mer - FRANCE
Warranty: 6 years, parts and labour, wear parts excluded
2 years for electric motor
This equipment is designed and manufactured in FRANCE.
This equipment should be used only by firefighting professionals
Construction:
1.1KW (1.5hp) 115V±10% - 50/60 Hz- motor TEFC
Operates on
15 amp circuit breaker with up to 200ft of 10awg wire
GFCI compatible
Nominal maximum current required: 13.9 amps
A high-tech composite grid
Impeller made of composite resin -
ø 16.5” – aluminium hub
Noise level +/- 85.2 dB(A) at 10ft
UL motor certification
Retractable handle
Angle of tilt adjustable (from 10° to 20°).
Airflow 17010cfm
Warning
: Always keep your hands away from moving parts.
Before starting:
Regardless the power supply (whether it be mains or generator) make
certain that the necessary energy is present and stable in tension and
frequency (N/-10%) before plugging the device.
1.
Use wiring strengths which are compatible with the installed capacity.
2.
Place the
EVG230 NEO
fan on a flat surface with no slippery products or debris, and
make sure that there is no obstacle between the fan and the opening for air entry.
Starting the motor:
1
. Start the fan after making sure that it is in a stable position.
2
. Switch the potentiometer on the
▌position to start the fan.
3
. Adjust the potentiometer on the power prefered from 0 à 100%.
Stopping the motor:
1.
Move the potentiometer on the
o
position.
-
For security reasons, in case of a power cute, the unit does not start off
automatically. To restart the potentiometer should be returned to
o.
USE WITH PORTABLE GENERATING SETS:
Electric motors require a high level of power to start up. If the
EVG230 NEO
ventilator is
used with a portable generating set,
Leader North America
. recommends that a minimum
power level of 3kVA should be available.
490
558
To tip
20°
10°
To
unlock
To lock
Weight : 78.3 lbs
+/- 1lbs
A
US
H=21.96
’’ W=21.65’’
D=19.29
’’
+/- .
5’’