5.3 

Control 

To remotely control the LV 7390 from this instrument, follow the procedure below. 

 

1.    Turn on this instrument and the LV 7390

.

 

This instrument does not have a power switch. Simply connect the power cord. When 
this instrument turns on, the POWER LED will light. 

 

2.    Connect this instrument’s Ethernet port to the LV 7390 Ethernet port using an Ethernet 

cable. 

The Ethernet cable is not included. You will need to provide it yourself. You can use a 
straight cable or a crossover cable. 
When the connection between this instrument and the LV 7390 is established, the 
ETHERNET LED lights. If it doesn’t, check section 5.1, “Configuring the LV 7390” and 
5.2, “Configuring the LV 7290” again. 
Note that the ETHERNET LED remains lit for a while even after the Ethernet cable is 
removed. 

 

●   

Control

 

When the ETHERNET LED is lit, the LV 7390 selected with the unit key can be remotely 
controlled from this instrument. 
You can also control the LV 7390 directly. If you do, the key operation performed on the 
LV 7390 selected with the unit key is reflected to this instrument. 

 

●    Notes 

• 

  Multiple LV 7390s cannot be controlled simultaneously from this instrument.   

(It is possible to connect several of this instrument to an LV 7390 and control it 
simultaneously.) 

• 

  USB memory devices and headphones cannot be connected to this instrument. 

• 

  The LV 7390 cannot be turned on and off from this instrument. 

 

 

Содержание LV 7290

Страница 1: ...LV 7290 REMOTE CONTROLLER INSTRUCTION MANUAL...

Страница 2: ...ations 3 2 3 1 Control 3 2 3 2 Panel 4 2 3 3 Rear Panel Connectors 4 2 3 4 General Specifications 4 3 NAMES AND FUNCTIONS OF PARTS 5 4 BEFORE YOU BEGIN MEASURING 6 4 1 Attaching the Cover Inlet Stoppe...

Страница 3: ...tand If you have any questions about the contents of this manual please contact your local LEADER agent Symbols and Terms The following symbols and terms are used in this instruction manual and on the...

Страница 4: ...ossibility that the instrument has condensation within it wait for approximately 30 minutes before turning on the power Operating Humidity Range Use this instrument in an environment whose relative hu...

Страница 5: ...does not meet the standards could lead to fire If the power cord is damaged stop using it and contact your local LEADER agent Using a damaged power cord could lead to electrical shock or fire When rem...

Страница 6: ...h with mild detergent and wipe gently While cleaning make sure that foreign materials such as water and detergent do not enter the product If liquid or a metal object enters into the instrument fire o...

Страница 7: ...cope of Warranty This LEADER instrument has been manufactured under the strictest quality control guidelines LEADER shall not be obligated to furnish the following free services during the warranty pe...

Страница 8: ...Electronic components can be damaged by static discharge Static electricity can build up in the core wire of a coaxial cable Before connecting a coaxial cable to an I O connector of the instrument sh...

Страница 9: ...ctions Up to 8 units The LV 7290 can connect to multiple LV 7390s and control them exclusively The TELNET features of the LV 7290 and LV 7390 cannot be used simultaneously 2 3 Specifications 2 3 1 Con...

Страница 10: ...r Panel Connectors Ethernet Port Compliant Standard IEEE802 3 I O Connector RJ 45 Functions Key code transmission LED data reception Type 10Base T 100Base TX USB Port Type B Specifications USB 2 0 Fun...

Страница 11: ...the key lock 4 UNIT Selects the connection destination 5 ETHERNET Connected to the LV 7390 The LV 7390 is remotely controlled from this instrument through this port It also allows LV 7390 key operati...

Страница 12: ...ollow the procedure below Attaching the Cover Inlet Stopper 1 Cover the power cord with the cover inlet stopper 2 Push the cover inlet stopper until you hear a click to attach it to the AC inlet 3 Che...

Страница 13: ...rument the LV 7390 firmware version must be 2 0 or later You can view the firmware version on the INFORMATION screen or the startup screen If the firmware version is earlier than 2 0 remote control is...

Страница 14: ...to 192 168 0 1 If you use the factory default setting you will not need to carry out the procedure in section 5 2 Configuring the LV 7290 If you are going to connect the LV 7390 and LV 7290 in a one...

Страница 15: ...e case proceed to section 5 3 Control 5 2 1 Factory Default Settings The factory default settings of this instrument are as follows Table 5 1 Factory default settings Parameter Factory default value I...

Страница 16: ...indows7 8 10 USB2 0 CD ROM drive USB cable USB A male USB B male 1 Connect this instrument s USB port to the PC s USB port using a USB cable 2 Turn on this instrument This instrument does not have a p...

Страница 17: ...the connection between this instrument and the LV 7390 is established Figure 5 5 LV7290 screen SETUP 2 Enter the values This instrument s settings are shown under Remote Controller and the connection...

Страница 18: ...hts If it doesn t check section 5 1 Configuring the LV 7390 and 5 2 Configuring the LV 7290 again Note that the ETHERNET LED remains lit for a while even after the Ethernet cable is removed Control Wh...

Страница 19: ...Following information is for Chinese RoHS only LV 7290 2006 2 28 SJ T11364 2006 Hazardous Substances in each Part Parts Pb Hg Cd Cr PBB PBDE SJ T11363 2006 SJ T11363 2006 Ver 1...

Страница 20: ...LEADER ELECTRONICS CORP 2 6 33 Tsunashima Higashi Kohoku ku Yokohama 223 8505 Japan PHONE 81 45 541 2123 FAX 81 45 541 2823 http www leader co jp JAN 12 2017 Ver 1...

Отзывы: