14. STATUS DISPLAY (STATUS)
175
14.4.1
Phase Difference Measurement Display Explanation
To display the phase difference measurement display, press F•3 EXT REF PHASE in the
status menu.
Figure14-11 Phase difference measurement display
1 Sync
signal
EXT appears here when an external sync signal is being used.Set the LV 5380 to
external sync to measure the phase difference between the input signal and an
external sync signal.
[Reference] Section
14.4.6, “Switching to an External Sync Signal”
2 Error
counter
The error counter, the current time, and the elapsed time are displayed here. For
details, see section 14.1, “General Status Display Explanation.”
3 V
PHASE
The phase difference in lines is displayed here.
4 H
PHASE
The phase difference is displayed here in microseconds (us) and sample numbers
(dot).
5 TOTAL
PHASE
The total of the V phase and H phase differences is displayed here in microseconds
(us).