149
13. STATUS DISPLAY
F•5
Procedure
● Selecting the Gamut Filter
If you are detecting gamut errors or composite gamut errors, you can set a low-pass filter to
remove transient errors such as overshoot.
To select the gamut filter, follow the procedure below.
Procedure
STATUS → F•5 ERROR CONFIG → F•4 ERROR LEVEL → F•1 GAMUT → F•5 GAMUT
FILTER: 1M / 2.8M / OFF
Settings
1M:
A 1 MHz low-pass filter is applied during error detection.
2.8M:
A 2.8 MHz low-pass filter is applied during error detection.
This option cannot be selected when the input signal is SD.
OFF:
A low-pass filter is not applied during error detection.
13.6.6
Configuring the Composite Gamut Error Settings
To configure the composite gamut error settings, press
STATUS menu.
COMPOSIT GAMUT on the
The settings that you specify here also apply to the CMP bar in the 5 bar display. The unit for setting the
level is the same as the unit that was specified with
Reference 12.8.1, “5 Bar Screen Description”
UNIT.
→
ERROR CONFIG →
ERROR LEVEL →
COMPOSIT GAMUT →
Figure 13-22 COMPOSIT GAMUT menu
● Setting the Upper Limit
To set the upper limit of composite gamut errors, follow the procedure below. An error is
detected when the level after converting the input signal to a pseudo-composite signal
exceeds the specified value.
Press the function dial (F•D) to return the setting to its default value (135.0, 963.9, or 945.0).
Procedure
→ F•5 ERROR CONFIG → F•4 ERROR LEVEL → F•2 COMPOSIT GAMUT
→ F•1 C.GAMUT UPPER %:90.0 - 135.0
→ F•1 C.GAMUT UPPER mV:
642.6 - 963.9 (for NTSC)
630.0 - 945.0 (for PAL)
● Setting the Lower Limit
To set the lower limit of composite gamut errors, follow the procedure below. An error is
STATUS → F•5 ERROR CONFIG → F•4 ERROR LEVEL → F•1 GAMUT
→ F•4 GAMUT DURATION: 1 - 50
F•2
F•6
F•4
F•2