USER MANUAL
Page 1 /2
ENVIRONMENTAL PROTECTION
Do not throw away the appliance with the normal household waste at the end of its
life, but hand it in at an official collection point for recycling. By doing this, you help to
preserve the environment.
COMPLIMENTS ON YOUR PURCHASE!
All dimensions are in millimeters
Package includes:
Content:
01
SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Safety instructions
01.3 Fire protection
02
PRODUCT SPECIFICATION
02.1 Technical specification
02.2 Product description
03
INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connection
03.4 Control data connection
03.5
DMX channels
04
PERMANENET USE LIMITATIONS
05
MAINTENANCE AND SERVICE
LL STAGE CYC 6C / 3C / 2C / 1C
02.2 Product description
03 INSTALLATION
03.1 Unpacking
- Unpack carefully.
- This is electronic equipment and should be handled carefully.
- Damaged delivered package or if are any mechanical parts broken – it must be
claim immediately by the transport company. Photo pictures as evidence are
valuable for future claim.
03.2 Physical installation
- Loading capacity of bearing area has to be at least 10 times the weight of all
device clusters.
- Hairbreadth from combustible materials is 0,5m.
03.3 Connection
- Respect all SAFETY INFORMATION 01!
- Connect the ground (earth) !
-
It is not necessary to open the fixture before power supply. Power supply is
solved simple with Neutrik PowerCon connectors.
-
The fixture is equipped with auto-switching power supply that automatically
adjusts to any AC 90 – 264 V, 47 – 63 Hz.
- Cord plug connections:
Symbol
Pin
Wire Colour
Screw (US)
L
live
brown
yellow or brass
N
neutral
blue
silver
ground (earth)
yellow/green
green
!
343
334
200
- LL STAGE CYC with adj. bracket
1pc.
- User manual
1pc.
Additional items needed:
- Data and power cables
- Controller compatible with DMX 1pc.
- Mounting accessories as necessary
Power Out
PowerCon
Power In
PowerCon
DMX Out
XLR-5pin
DMX In
XLR-5pin
Address
set-up
under cover
01 SAFETY INFORMATION
WARNING!!!
Carefully read before installing, powering or servicing. Nothing to do if
anything misunderstand! Installation can be done only by a qualified
professional in accordance with relevant local codes.
01.1 Risk of eyes damage
-
Do not look directly into LED lamps.
-
Do not look into light beam from a distance of less than 40 cm (16 inches)!
01.2 Safety instructions
- Shut down power before installation or maintenance.
- Do not modify, alter, or attempt to service the LEADER LIGHT appliance. Doing
so will void the warranty.
-
Appliance and recommended AC power supply must be installed by a qualified
professional in accordance with relevant local codes. Use only acceptable source
of AC power and frequency that complies with local biulding and electrical codes.
- Use only the recommended voltage source.
- Appliance always connect to earth (eltech.)!
- Do not use or do not connect the products if the power cable, power plug or
fixtures are any way damaged, wet, or if they are overheating.
- Before removing or installing any cover or part of appliance disconnect it from AC
power.
- AC power supply must be protected against overvoltage and short circuits.
01.3 Fire protection
- Follow all safety restrictions.
- Thermostatic switches or fuses never to bypass.
-
Device never shield. Around the axis of the fitting (180°) must be maintained space
for cooling. Minimum distance from the surrounding objects must be 100mm (4 in.).
-
LEDs never direct cover with filters or other materials.
-
Allowing max. ambient temperature is 40°C (104°F).
- Luminaries never use without mounting brackets. The housing never install
directly to the surface.
02 PRODUCT SPECIFICATION
02.1 Technical specification
Power connection:
AC 90 – 264 V, 47 – 63 Hz In/Out PowerCon
IP:
IP20
Control data:
DMX 512 In/Out with XLR 5pin
Ambient temp. (Ta):
Maximum 40°C
Net weight:
5kg
Installation:
Surface mounting
Cooling:
Active 5 dB @ 1 m
!
WARNING - Disconnect
mains before remove cover!
Made in EU
Leader Light s.r.o.
Slovakia, 20__
www.leaderlight.eu
AC/DC 90 – 264 V, 50/60 Hz
T max. 40° C
SN
LL Stage CYC 6C
LL Stage CYC 5C
LL Stage CYC 4C
LL Stage CYC 3C
LL Stage CYC 2C
LL Stage CYC 1C
POWER
POWER IN
DMX IN
POWER OUT
DMX OUT
MADE IN
SLOV
AKIA
www.leaderlight.eu