background image

©MMXI - LEADER LIGHT – All right reserved

Edition: A - 2011

 Additional information on  [email protected]

LEADER LIGHT s.r.o.

M.Gorkeho 33

052 01 Spisska Nova Ves

Slovakia

www.leaderlight.eu

USER MANUAL

 Page 1 /2

ENVIRONMENTAL PROTECTION

Do not throw away the appliance with the normal household waste at the end of its 

life, but hand it in at an offi cial collection point for recycling. By doing this, you help to 

preserve the environment.

COMPLIMENTS ON YOUR PURCHASE!

All dimensions are in millimeters

Package includes:

Content:

01

SAFETY INFORMATION

01.1 Risk of eyes damage
01.2 Safety instructions
01.3 Fire protection

02

PRODUCT SPECIFICATION

02.1 Technical specifi cation

02.2 Product description

03

INSTALLATION

03.1 Unpacking
03.2 Physical installation
03.3 Connection
03.4 Control data connection
03.5 DMX channels

04

MAINTENANCE AND SERVICE

01   SAFETY INFORMATION

WARNING!!!

Carefully read before installing, powering or servicing. Nothing to do if 

anything misunderstand! Installation can be done only by a qualifi ed 

professional in accordance with relevant local codes.

01.1 Risk of eyes damage

Do not look directly into LED lamps.

Do not look into light beam from a distance of less than 40 cm (16 inches)!

-

-

01.2 Safety instructions

Shut down power before installation or maintenance. 

Do not modify, alter, or attempt to service the LEADER LIGHT appliance. Doing 

so will void the warranty.

Appliance and recommended AC power supply must be installed by a qualifi ed 

professional in accordance with relevant local codes. Use only acceptable source 

of AC power and frequency that complies with local biulding and electrical codes.

Use only the recommended voltage source.

Appliance always connect to earth (eltech.)!

Do not use or do not connect the products if the power cable, power plug or 

fi xtures are any way damaged, wet, or if they are overheating.

Before removing or installing any cover or part of appliance disconnect it from AC 

power.

AC power supply must be protected against overvoltage and short circuits.

-

-

-

-

-

-

-

-

01.3 Fire protection

Follow all safety restrictions.

Thermostatic switches or fuses never to bypass.

Device never shield. Around the axis of the fi tting (180°) must be maintained space 

for cooling. Minimum distance from the surrounding objects must be 100mm (4 in.).

LEDs never direct cover with fi lters or other materials.

Allowing max. ambient temperature is 40°C (104°F).

Luminaries never use without mounting brackets. The housing never install 

directly to the surface. 

-

-

-

-

-

-

02   PRODUCT SPECIFICATION

02.1 Technical specifi cation

Power connection:

100-260V AC 50-60Hz In/Out PowerCon

IP:

IP20

Control data:

DMX 512 In/Out with XLR 5pin

Ambient temp. (Ta):

Maximum 40°C

Net weight:

6kg

Installation:

Surface mounting

!

LL STAGE 6-06D

LL36 

080

02.2 Product description

Indication of control LEDs (LED power- green,LED data - yellow)

LED

Indication

Status

LED Power

blinking - 2Hz

O.K. - Device is working correct

LED Data

not lit

No DMX signal

LED Data

blinking - 4Hz

O.K. - Correct DMX signal

LED Data

fast blinking

ERROR - Incorrect digital signal

LED Power & 

LED Data

alternating blinking

function AutoTest

03 INSTALLATION

03.1 Unpacking

Unpack carefully.

This is electronic equipment and should be handled carefully.

Damaged delivered package or if are any mechanical parts broken – it must be 

claim immediately by the transport company. Photo pictures as evidence are 

valuable for future claim.

-

-

-

03.2 Physical installation

Loading capacity of bearing area has to be at least 10 times the weight of all 

device clusters.

Hairbreadth from combustible materials is 0,5m.

Before physical installation insert the optic modul on front of luminary. The optic 

installation is easy and  fast by 2 screws. (fi gures Nr. 2.1 to 2.2)

-

-

-

03.3 Connection

Respect all SAFETY INFORMATION 01!

Connect the ground (earth) !

It is not necessary to open the fi xture before power supply. Power supply is 

solved simple with Neutrik PowerCon connectors.

The fi xture is equipped with auto-switching power supply that automatically 

adjusts to any 50-60Hz AC power source from 100-260V.

Cord plug connections:

-

-

-

-

-

Symbol

Pin

Wire Colour

Screw (US)

L

live

brown

yellow or brass

N

neutral

blue

silver

ground (earth)

yellow/green

green

!

LL STAGE 6-06D with adjustable bracket

-

1pc.

PowerCon type “A“ + “B“

-

1pc.

User manual

-

1pc.

Additional items needed:

Data cables with XLR 5pin F/M

-

1pc.

Controller compatible with DMX

-

1pc.

Mounting accessories as necessary

-

610

164

98

DMX Out

XLR-5pin

DMX In

XLR-5pin

Power In

PowerCon

Power Out

PowerCon

Power In

Data In

Power Out

Data Out

!

!

Non-minimum distance and / or non-use the original brackets is at your own risk!

WARNING!!!

Отзывы: