background image

USER MANUAL

LL ARC MINI LINE WHITE

Leader Light s.r.o.

M.Gorkeho 33

SK-052 01 Spisska Nova Ves

Slovakia

www.leaderlight.eu

LL40 205

ENvIRoNMENT

Do not throw away the appliance with the normal household waste at the end of its life, 

but hand it in at an official collection point for recycling. By doing this, you help to preserve 

the environment.

WARNING!!!

Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only 
by a qualified professional in accordance with relevant local codes.

01    SAfETy INfoRMATIoN

01.1 Risk of eyes damage

Do not look directly into LED lamps.

Do not look into light beam from a distance of less than 40 cm (16 inches)!

-

-

01.2 Protection from electric shock

Shut down power before installation or maintenance.

Luminaries, Driver and recommended power supply must be installed by a qualified 

professional in accordance with relevant local codes. Only acceptable source of power and 

frequency that complies with local building and electrical codes to use.

Do not use or do not connect the products if the power cable, power plug or fixtures are any 

way damaged, wet, or if they are overheating.

Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the 

warranty.

Before removing or installing any cover or part of appliance disconnect from power.

-

-

-

-

-

01.3 fire prevention

Follow all safety consideration.

Thermostatic switches or fuses never to bypass.

Device never shield – minimum distance around fitting must be 50mm (2 in.).

LEDs never direct cover with filters or other materials.

Allowing max. ambient temperature is 40°C (104°F).

-

-

-

-

-

02 PRodUCT SPECIfICATIoN

02.1 Technical Specification

03 INSTALLATIoN

03.1 Unpacking

Unpack carefully.

This is electronic equipment and should be handled carefully.

Damaged delivered package or if are any mechanical parts broken – it must be claim 

immediately by the transport company. Photo pictures as evidence are valuable or 

future claim.

-

-

-

03.2 Physical installation

Loading capacity of bearing area has to be at least 10 times the weight of all device 

clusters (luminaries, clamps, cables, ...).

Hairbreadth from combustible materials is 0,5m.

-

-

©MMX - Leader Light – All right reserved

If you have any question please, contact [email protected]

CoMPLIMENTS oN yoUR PURCHASE!

LL40 215 LL40 225

Content:
01   SAfETy INfoRMATIoN

        01.1 Risk of eyes damage

        01.2 Protection from electric shock

        01.3 Fire prevention

02   PRodUCT SPECIfICATIoN

        02.1 Technical Specification

03   INSTALLATIoN

        03.1 Unpacking

        03.2 Physical installation

        03.3 Electrical installation

                03.3.1 Connecting to AC/DC power supply

                03.3.2 Connecting to LL ARC DRIVER for intensity/colour control

04   MAINTENANCE

03.3.1 Connecting to dC power supply 

(Figure Nr. 1.1)

LL ARC MINI LINE must be connected to the device- MW power supply                 

IN:100-260AC/ OUT: 24V.

It is not necessary to open fixture before connecting to MW power supply.

   

AC Power Supply Cord plug connections to MW Power supply:

-

-

Symbol

Pin

Wire Colour

Screw (US)

L

live

brown

yellow or brass

N

neutral

blue

silver

ground (earth)

yellow/green

green

03.3.2 Connecting to LL LEd dRIvER 

(Figure Nr. 1.2)

For intensity and colour control is necessary connection with LL ARC DRIVER.

It is not necessary to open fixture before connecting to LL ARC DRIVER.

Before installing of LL ARC DRIVER carefully read USER MANUAL for LL ARC DRIVER.

-

-

-

03.3 Electrical installation

To tackle all Safety Information- 01!

You can suffer a dangerous electric shock by using a high voltage AC/DC 

power supply - by touching the AC/DC power supply wires inside LL ARC MINI LINE!

LL ARC MINI LINE can be operated in two ways:

      - 03.3.1 LL ARC MINI LINE connecting to DC POWER SUPPLY - for switch ON/OFF 

        luminaries

      - 03.3.2 LL ARC MINI LINE connecting to LL ARC DRIVER - for intensity and colour

        control

-

-

-

Edition: A - 2010

All dimensions are in milimeters

Φ

38

Lamp type:

1200mm: 96xW TOP LED (White)

  600mm: 48xW TOP LED (White)

  300mm: 24xW TOP LED (White)

Lifetime:

Long 100 000 hrs 60% degradation

view Angle:

120°

Control data Input:

1 channel 24V dimming

Power input:

1200mm: max. 8W

  600mm: max. 4W

  300mm: max. 2W

Power connection:

24V DC 5m cable with 6pin LINE connector

Net weight:

1200/600/300mm: 1kg/ 0,6kg/ 0,3kg

Dimensions LxΦ: 

1200/600/300mm x 38mm without bracket

IP:

IP20

Ambient temp. (Ta):

Maximum 40°C

Cooling:

Conventional

Materials and finish:

End cups: plastic

Cover: frosted PMMA

Installation:

Any position for ceiling, wall and surface-mounting

300

600

1200

  operation only with dC 24v source! By using a high voltage AC power supply-danger  

  of electric shock!

following items are included:

- LL ARC MINI LINE with 5m cable and 6pin LINE connector

1 pc.

- LL BRACKET MINI LINE FIX

1 pc.

- User manual

1 pc.

Additional items needed:

- LL ARC DRIVER
- DC power supply 24V
- Controller compatible with DMX 
- Mounting accessories (adjustable bracket)
- Screws and washers M6