15 Appendix
Charging Characteristics
NOTE!
To select the correct charging characteristic for your battery, refer to
the instructions of your battery manufacturer.
NOTE!
The current, compared to the nominal capacity, is given in coulombs
(C), e.g. 0.2 C for a 100 Ah battery results in 20 A.
LK10-05 - Freely ventilated lead-acid
Fig. 6: Charging characteristic LK10-05
In the “Top-Fill” charging phase, the battery is charged with +15% more current
compared to the main charging phase.
In the range [-30 °C ... -35 °C] and [+45 °C ... +60 °C] the current is reduced to
0.
Voltage per cell
12 V system
24 V system
2.4 V/ 2.8 V/ 2.29 V
14.4 V/ 16.8 V/ 13.74 V
28.8 V/ 33.6 V/ 27.48 V
22
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
15 Appendix
LEAB Automotive GmbH
Содержание 0101036081
Страница 29: ...29 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...
Страница 30: ...30 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 15 Appendix LEAB Automotive GmbH...
Страница 31: ...31 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...