background image

Le Maitre Ltd. 

 

Salamander User Manual 

 

15 

 

8.

 

Maintenance 

 

 

Please note:

 While the Salamander contains several components that have been designed 

to be user-serviceable, the maintenance procedures described in this section should only 
be performed by qualified personnel. The manufacturer cannot be held responsible for 
events occurring due to incorrect maintenance of this machine. 

 

Please note:

 All the procedures described in this section should be performed with the 

Salamander isolated from any power supply, after the unit has been allowed to cool for at 
least 10 minutes. 

 

The Salamander features a service panel secured by 4xM4 bolts. Removal of this service panel allows 
access to the majority of user-serviceable components within the Salamander: 

 

Figure 4: Salamander Firing Mechanism 

 

 

 

Содержание Salamander

Страница 1: ...Salamander Flame Effect System User Manual Version 1 3 January 2020 ...

Страница 2: ...y the manufacturer or after the manufacturer s strict approval Should there be any doubt as to the safety of operation of the machine under any circumstances the machine should be taken out of service immediately The Salamander must not be used in confined spaces under any conditions of rain snow or precipitation of any fluids or moving air which will cause the flame to divert from a vertical path...

Страница 3: ...sing the Salamander This includes persons in the performance area and surrounding flammable objects Minimum safety distances are as follows o Horizontal radius 2 metres o Vertical safety height 8 metres for a single unit or 2 units coupled in a single location o Vertical safety height 10 metres if three or more units are coupled in a single location Full risk assessments must be made before use an...

Страница 4: ... for safe operation this will be deemed the responsibility of the operator Avoid live wiring DMX to the Salamander ie do not plug in or unplug DMX cables while the controller is actively transmitting data The Salamander is not designed for continual flame use It is intended for short duration bursts ie maximum duration of 5 seconds Should the Salamander fail to fire correctly immediately shut down...

Страница 5: ...6 4 3 Specification 7 5 Operation 8 5 1 Getting Started 8 5 2 Control Panel 9 5 3 DMX Operation 9 5 4 Set Up 10 5 5 Coupling Units 11 5 6 Fixing points 12 5 7 Shutdown 12 6 Advanced Settings 13 6 1 DMX Filter 13 6 2 Tilt Switch 13 7 Troubleshooting 14 8 Maintenance 15 8 1 Solenoid Testing 16 8 2 Firing Pin Adjustment 16 8 3 O Ring Replacement 17 8 4 HSI Testing 18 9 Contact Details 19 10 Warranty ...

Страница 6: ...Le Maitre Ltd Salamander User Manual 5 3 Features and Dimensions Figure 1 Salamander Features and Dimensions All dimensions are in millimetres ...

Страница 7: ...ve propane bottles and high pressure hosing and allows for a choice of fuels making the Salamander ideal for any venue where propane is not permitted Details of the full range of Le Maitre products are available online at www lemaitreltd com and www lemaitreusa com 4 2 Features 4m high flame effect from a single unit Over 6m high flame effect from 4 coupled units Canister based system Multiple col...

Страница 8: ...VAC 60Hz 250W External Fusing EU US 3 15AT 6 3AT Fuel Capacity 1 x 500ml Canister Fuel Type Propane Butane mix OR Ethanol Methanol mix colour specific Effect Duration 30s continuous up to 50 fireballs Control DMX512 2 Channels Igniter Fire Dimensions mm 433 H x 170 W x 204 D including handle Weight 10kg ...

Страница 9: ...allows for daisy chaining multiple DMX units together on a single DMX output from the controller For safety it is advised that such network be reserved for flame units Power is supplied to the Salamander via the blue Neutrik PowerCon socket A suitable mains cable fitted with a blue PowerCon plug must be used to connect the Salamander to a mains supply The white PowerCon socket is a mains through c...

Страница 10: ...the HSI has had time to reach full temperature While the timer is active the 3 digit display will flash When the display stops flashing the unit is ready to fire When the Fire channel is raised above 50 a solenoid forces a plunger into the fuel canister opening the canister valve and allowing the pressurised fluid to escape via the output nozzle located at the base of the flue It is recommended th...

Страница 11: ...ons to cycle through DMX channels When the desired channel is selected press STORE VIEW to save the setting Press SELECT again and the FLAME indicator LED will light up This is the Fire channel Select the desired channel and save it as above Pressing SELECT again will return to the DMX status display Setting HSI Delay Press STORE VIEW and UP simultaneously dEL will scroll across the display follow...

Страница 12: ...Daisy chaining Mains and DMX connectors allows for the entire effect to be powered and controlled by a single mains supply and DMX line respectively Please note The US 120VAC model will draw a peak current of about 7 Amps when the ignitor is activated This inrush current will last for less than a second and settle rapidly to a steady state current of about 1 5 Amps However this means four coupled ...

Страница 13: ... they will be supplied fitted with M6x16 bolts On the front they are used to secure the handle to the unit The handle can be removed and the fixing points can be used for other purposes Fixing point spacings are as follows Front 93 5mm Rear 46 75mm 5 7 Shutdown Each of the following steps disables the machine The order presented is for a recommended normal shutdown procedure In case of an emergenc...

Страница 14: ...the display followed by the setting F 1 indicates the filter is switched on 5 Press UP and DOWN to toggle between filter on F 1 and filter off F 0 6 2 Tilt Switch The Salamander contains a safety tilt switch that will disable the unit if it is tipped beyond 40 degrees from vertical This will prevent the unit from operating should it be knocked over It is possible to disable this tilt switch if des...

Страница 15: ...to Maintenance instructions contact Le Maitre Firing solenoid not activating HSI still heating Wait until HSI is fully heated The display will stop flashing when the Salamander is ready to fire Incorrect DMX channel Set to correct DMX channel Refer to Set Up instructions Firing solenoid activating but no gas released Empty canister Replace canister Canister nozzle damaged Replace canister Firing p...

Страница 16: ...be held responsible for events occurring due to incorrect maintenance of this machine Please note All the procedures described in this section should be performed with the Salamander isolated from any power supply after the unit has been allowed to cool for at least 10 minutes The Salamander features a service panel secured by 4xM4 bolts Removal of this service panel allows access to the majority ...

Страница 17: ...ing The firing solenoid should never be continuously activated for more than 30 seconds Keeping the solenoid powered for extended periods risks damage to the solenoid coil 8 2 Firing Pin Adjustment While the firing solenoid is not active the firing pin should not protrude above the top surface of the canister base Figure 5 Correct and Incorrect firing pin positions If the pin protrudes above the t...

Страница 18: ...he brass canister base The other is located on the firing pin The canister base O ring should be inspected every time the canister is changed If the rubber appears worn frayed or split the O ring should immediately be replaced It might be necessary to cut the O ring out of the canister base using a small blade such as a scalpel The replacement O ring can simply be pressed into place It is recommen...

Страница 19: ...ould be applied to the O ring and any excess should be wiped away When the O ring has been replaced re install the firing pin Please note Under no condition should the firing pin be pushed up out of the top if the canister base This will force the firing pin O ring across the canister base s side opening damaging the rubber and compromising the seal created Warning Failure to apply lubricant to th...

Страница 20: ...aitre Ltd 6 Forval Close Wandle Way Mitcham Surrey CR4 4NE Tel 44 0 20 8646 2222 Fax 44 0 20 8646 1955 Email info lemaitreltd com USA Le Maitre USA LLC 13975 Grand Valley Parkway Las Vegas NV 89165 USA Tel 1 512 451 4392 Fax 1 206 350 3553 Email info lemaitreusa com ...

Страница 21: ...ects providing that the unit has been regularly serviced by an authorized agent and has only used genuine Le Maitre Canisters Le Maitre Ltd considers all of its products to be safe for use in the application it was intended Le Maitre Ltd takes no responsibility for misuse or incorrect use Always refer to the equipment owner s manual for proper use and be aware of local legislation governing the pr...

Страница 22: ...Le Maitre Ltd Salamander User Manual 21 Le Maitre Ltd 6 Forval Close Wandle Way Mitcham Surrey CR4 4NE Le Maitre is a registered trademark of Le Maitre Ltd ...