the channel value is increased the snow machine should produce snow at
a steadily increasing rate. The unit is OFF when a value between 0-5 is
selected. It will reach 100% output once the channel is set to 255.
DMX protocol
DMX value
0-5
6-255
OFF
ON
Addressing
Each device occupies 1 channel. To ensure that the control signals are
properly directed to each device they will need to be addressed. This will need
to be adjusted for each device by changing the DIP-switches as set out in the
table below.
The starting address is defined as the first channel from which the device will
respond to the controller. Make sure that you do not have any overlapping
channels in order to control each device correctly and independently from any
other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Setting the
DMX-starting
address:
DIP-switch
no.
1 2 3 4 5 6 7 8 9
Device number
& channels
Starting
address
1 2 4 8 16
32
64
128
256
ON
▲
Device 1 - Channel 1
OFF
▽
▽
▽
▽
▽
▽
▽
▽
ON
▲
Device 2 - Channel 2
OFF
▽
▽
▽
▽
▽
▽
▽
▽
ON
▲
▲
Device 3 - Channel 3
OFF
▽
▽
▽
▽
▽
▽
▽
ON
▲
Device 4 - Channel 4
OFF
▽
▽
▽
▽
▽
▽
▽
▽
ON
▲
▲
Device 5 – Channel 5
OFF
▽
▽
▽
▽
▽
▽
▽