s88-ClockMaster-G

 Part-No.:

 090023

 

 
 

>> finished module in a case<< 

 
 

 
 
 

To be used as timing generator for the s88-
feedback bus to operate the switch board light 
decoder GBS-DEC-s88 without the connection 
to a digital control unit or to a PC with model 
railway software. 

 
 
 
 
 
 
 
 
 

This product is not a toy! Not suitable for children under 14 years of age! 
The  kit  contains  small  parts,  which  should  be  kept  away  from  children  under  3! 
Improper use will imply danger of injuring due to sharp edges and tips! Please store 
this instruction carefully. 

 

 

 

 

 

 

 

 
 

  
 
 
 
 
 
            

Introduction / Safety Instruction: 

 

You  have  purchased  the  s88-ClockMaster  for  your  model 
railway supplied within the assortment of Littfinski DatenTechnik 
(LDT). 

 

We are wishing you having a good time using this product. 

 

  Please  read  the  following  instructions  carefully. Warranty  will 

expire due to damages caused by disregarding the operating 
instructions. LDT will also be not liable for any consequential 
damages caused by improper use or installation. 

 

The finished module in a case comes with a 24 month warranty

 

Connecting the s88-ClockMaster with the 

switch 

board  light  decoder  GBS-DEC-s88  and  eventually 
with the 

Service-Module: 

  Attention:  Before  starting  the  installation  switch  off  the 

drive voltage by pushing the stop button or disconnect the 
main supply to all transformers.
 

 

Each  switch-board  light  decoder  GBS-DEC-s88

 

will  be 

supplied together with a 2 Meter s88-Bus Cable
Connect the one side of the bus cable onto the 6-poles pin bar of 
the  switch-board  light  decoder  GBS-DEC-s88  marked  with 
s88-Out”. Connect the other side of the cable to the 6-poles pin 
bar of the s88-ClockMaster marked with “s88-Bus” in a way that 
the  direction  of  the  cable  shows  away  from  the  PC-board. 
Additionally attend to the white marking at one end of the pin 
bar
. This mark has to correspond to the white single wire of 
the respective cable. 
 
For adjusting the quantity of feedback modules which the s88-
ClockMaster
  has  to  consider  additionally  the  Service  Module 
GBS-Service is required. 

Connect  the  15-poles  pin  bar  of  the  Service-Module  GBS-
Service
  to  the  15-poles  socket  bar  of  the  s88-ClockMaster
The inserted pin bar shall have no offset to the socket bar. 

 

The  s88-ClockMaster  receives  the  voltage  supply  via  the  
2-poles clamp KL1
If the switch-board light decoder GBS-DEC-s88

 and the 

s88-

ClockMaster  receives  the  power  supply  from  a  common 
transformer
  you  have  to  attend  to  the  correct  polarity  of  the 
supply  voltage.  Important  is  the  identification  “yellow”  and 
brown” at the clamps. The sample connection on the rear side 
of this instruction shows the correct wiring

 

Getting started: 

 

If the s88-ClockMaster receives power supply the green LED 
will  glow  after  a  short  time  and  indicates  the  mode  ready-to-
operate
. The bus-clock timing will be created. The bus-clock can 
be switched-on or -off with the keys Stop and Go. The red LED 
will glow if the bus-clock has been switched-off
A  total  of  32  16-fold  Feedback  Modules  can  be  controlled  by 
one s88-ClockMaster. The factory setting is on 6 units. 
As  the  processing-  respectively  response-time  of  the 
feedback  system  depends  on  the  quantity  of  Feedback 
Modules
 is it important to make a correct setting of the actual 
connected feedback modules. For this adjustment you have to 
switch-off  the  s88-ClockMaster  and  connect  the  Service 
Module GBS-Service

 

Adjusting the quantity of Feedback-Modules: 

After  switching-on  the  s88-ClockMaster  the  display  of  the 
Service-Module  indicates  s88-CM  Vx.yy.  If  the  display  of  the 
service module shows no correct image after first switching into 
operation  please  turn  careful  the  Trim-Pot  R1  with  a  small 
screw  driver
  a  half  turn  left  and  right  until  you  can  read  the 
display information optimal.  

 

On the Service-Module you can find 4 push buttons which are 
indicated  within  the  following  instruction  with  >links<  (>left<), 
>rechts< (>right<), >oben< (>top<) and >unten< (>bottom<) 

 
 
 
 
 
 

At  first  push  the  key  >rechts<  (>right<).  By  first  operation  the 
display will indicate the text Anzahl (qty)  RM:06. With the key 
>oben< (>top<) or >unten< (>bottom<) you can now adjust the 
number of feedback modules between 1 and 32
Now activate the key >links< (>left<) or >rechts< (>right<). 
The  s88-ClockMaster  will  leave  the  setting  mode  and  after  a 
short period the display of the service module indicates s88-CM  
Vx.yy

 

Now is the s88-ClockMaster in operation mode. 

 

For the further operation is the Service-Module not necessarily 
required. Eventually you can detach it from the s88-ClockMaster 
provided that the supply voltage has been switched-off and the 
display is blank. 

 

 

 

 

KL1

s8

8-b

us

gelb     braun

14...18V~

Littfinski  DatenTechnik  (LDT)

B

U

1

ST

1

S1

S2

LE

D1

LE

D2

ST

2

Sto

p

Go

Go

Sto

p

bo

os

te

r

+

+

s88-ClockMaster

Rev 1.0

s88-CM

Erzeugt den s88-Takt für den Gleisbildstellpult-
Decoder GBS-DEC-s88.

s88-ClockMaster
s88-CM

Digital-Profi werden!

Littfinski DatenTechnik (LDT)

www.ldt-infocenter.com

Отзывы: