Arrow Board Operators Manual V1.2          

 

 Page 1 of 12 

 

LDC EQUIPMENT 

 LDC AB-C Size Arrow Board

 

Installation and Instruction Manual 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 

 

 

        Single Sided Arrow Board Controller               

 

Quality Management System Approved to  

AS/NZS ISO 9001:2008 – Reg. C31071 

 

 

 

N21990 

Содержание LDC ABC

Страница 1: ...ors Manual V1 2 Page 1 of 12 LDC EQUIPMENT LDC AB C Size Arrow Board Installation and Instruction Manual Single Sided Arrow Board Controller Quality Management System Approved to AS NZS ISO 9001 2008...

Страница 2: ...duction 3 LDC AB C Arrow Board 4 Sign Positioning 5 Inside the Control Box 5 Arrow Board Operation 6 Operation 6 Controller Operation Modes for Arrow Board 7 Fail Safe Techniques Employed 7 Troublesho...

Страница 3: ...tor that provides for disconnection of power in the event that service is required or in the event of an overload The controller screen displays the current operation mode and a real time mimic of the...

Страница 4: ...Page 4 of 12 LDC AB C Arrow Board AC4S Controller Single and Double sided Arrow Boards Isolator switch Optional Beacon Switch OLED Display Screen Control Knob LED Lamps with Visors Light Sensor Solar...

Страница 5: ...d Deploy the stabilising legs from their travelling position horizontal to their set up position vertical by pulling out the spring loaded leg locking pin and pivoting the leg 90 degrees until the loc...

Страница 6: ...l knob so that the pointer points to the desired mode to be displayed on the sign The mode selected on the controller will be illuminated on the sign as viewed from the REAR of the vehicle When switch...

Страница 7: ...ime what the sign is displaying During the normal operation of the system the AC4S controller communicates continually with the Arrow Board computer requesting the current status of the Arrow Board Sh...

Страница 8: ...ght sensor mounted at the bottom of the Arrow Board If the LED display on the controller does not light check the isolator switch to ensure it is in the ON or RESET position In the event of a failure...

Страница 9: ...ck the wiring from the battery to the controller for poor connections Replace the battery if necessary Lamp Fault One or more lamps have failed Visually check operation of lamps check lamp connections...

Страница 10: ...ing the unit DO NOT USE THE EQUIPMENT FOR ANY OTHER PURPOSE THAN IT WAS INTENDED FOR Maintenance On a WEEKLY basis perform the following activities to ensure safe trouble free operation of the equipme...

Страница 11: ...r replaced for a period of 12 months Any sign that has failed as a result of a traffic accident abuse or act of vandalism or incorrect use after delivery shall not be covered under warranty provisions...

Страница 12: ...onal Warning Controls Power Isolation Switch Circuit Breaker Mode Selection Switch Rotary Encoder Mode Indication LEDs 4 LEDs Beacon operation Toggle Switch Lamp Brightness 625 cd Minimum 0 0 Axis 100...