Article No. : 06456 (Factory Ref. No. LD-576)

INSTRUCTION MANUAL

TALKING

 

AUTOMATIC

 

DIGITAL BLOOD PRESSURE MONITOR

Содержание LD-576

Страница 1: ...Article No 06456 Factory Ref No LD 576 INSTRUCTION MANUAL TALKING AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR...

Страница 2: ...NENTS 1 13 2 3 4 5 6 7 8 10 9 11 12 1 Main Body 2 Display 3 Air Connector 4 Tube Plug 5 Air Hose 6 Cuff 7 D ring 8 Button M1 9 Button M2 10 Button 11 Batteries Not Included 12 Adapter Not Included 13...

Страница 3: ...Keep dry Attention consult accompanying documents Type BF Applied Part Stand by Symbol for the marking of electrical and electronics devices according to Directive 2002 96 EC The device accessories a...

Страница 4: ...TIME 9 VOLUME ADJUSTMENT 10 SETTING THE LANGUAGES 11 FUNCTION OF MEMORY MEMORY RECALL MEMORY CLEARANCE 12 WHO BLOOD PRESSURE CLASSIFICATION INDICATION 13 IRREGULAR HEARTBEAT DETECTOR 14 ERROR AND LOW...

Страница 5: ...oscillometric technology with Fuzzy Algorithm to measure the arterial blood pressure and pulse rate The cuff is wrapped around the arm and automatically inflated by the air pump The sensor of the devi...

Страница 6: ...ood pressure measurement in room temperature approximately 20 If this device was stored in low temperature it is necessary to leave it in room temperature for at least 1 hour otherwise the measure men...

Страница 7: ...e disease 10 15minutes interval is also applicable for patients suffering from diabetes for a long period of time 4 It is necessary to keep quiet during measurement to get accurate readings Measuremen...

Страница 8: ...leave the worn batteries in the device Besides batteries you can use AC power adapter as the power supply The AC power adapter is optional for this device for sale Insert the AC adapter cord into the...

Страница 9: ...cuff on the upper arm is approximately at the same level as the hear 1 Sit beside the table and let the table support your arm as you take the measurement Make sure that the cuff on the upper arm no...

Страница 10: ...he cuff to make sure that it is attached securely The cuff should not be too tight or loose is greatly recommended Two fingers should be easily put in between cuff and upper arm 5 The mark INDEX on th...

Страница 11: ...s not sufficient to determine measurement result 6 The heart symbol start to flash every heart beat once pulse is detected when pressure falls as in Fig 2 7 If irregular heartbeat was detected during...

Страница 12: ...as in Fig 6 3 Press button M1 or M2 to subtract or add the number and press button for confirmation 4 When the year setup is finished the month number will flash automatically Please follow the same...

Страница 13: ...guages 3 Press button when you have finished setup If you want to change the languages please repeat the above procedure L1 English L2 French L3 German Annotation 1 The icon L1 in the LCD indicates th...

Страница 14: ...emory Press button M1 or M2 the display will show the average value of the latest 3 readings with a voice prompt as in Fig 9 3 Press again the display will show 01 which means the latest reading then...

Страница 15: ...zation standard your blood pressure level is Mild Hypertension Note If the systolic blood pressure and the diastolic blood pressure fall into different categories the higher value should be taken for...

Страница 16: ...he device 5 The cuff is sensitive and must be handled with care You can clean the cuff with damp cloth for daily maintenance To avoid cross infection when sharing the cuff you can sterilize the fabric...

Страница 17: ...the measurement Take measurement again after resting for more than 5 minutes Use alkaline batteries of known manufacturers Is the cuff at the same level as the heart Is the cuff wrapped right Did you...

Страница 18: ...1 5V Optional component 6V 600mA 3 mmHg for static pressure 5 of the reading for the pulse rate Approximately 310g without batteries Weight Measuring method Measuring range Measuring accuracy Inflati...

Страница 19: ...Tongxing Road Economic Technological Development Area 226009 Nantong City PEOPLE S REPUBLIC OF CHINA HONSUN NANTONG Co Ltd Address Eiffestrasse 80 20537 Hamburg GERMANY SHANGHAI INTERNATIONAL HOLDING...

Страница 20: ...for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec 1 kV differential mode Mains power quality should be that of a typical commercial or hospital...

Страница 21: ...according to the transmitter manufac turer and d is the recommended separation distance in metres m b Field strengths from fixed RF transmitters as determined by an electromagnetic site survey c shou...

Страница 22: ...uipment and the LD 576 Digital Blood Pressure Monitor The LD 576 Digital Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled T...

Страница 23: ...BPM different from procedures or instructions of the manual 2 The body is damaged artificially 3 Self repairing or modifying the monitor construc tion in any way 4 Breakdown due to corrosion of batte...

Страница 24: ...The mentioned trademarks and names are owned by the corresponding companies If you use the device with power adapter preventive inspection and mainte nance to be performed including the frequency of s...