LCJ CAPTEURS CV3F series Скачать руководство пользователя страница 1

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
  
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

CV7 

 

ULTRASONIC WIND SENSOR 

CV7  is  an  updated  wind  sensor  based  on  the  CV3F  series,  already  having  a  world 
wide distribution. It is light, compact and has a small consumption. 
CV7  is  designed  to  fit  the  specific  needs  of  sailing  boats  through  an  easy  to  use 
programmable interface.

 

 

The  sensor  can  be  combined  with  a  P.C.,  either  with  normalised  NMEA

®

  input 

equipment or with any specialised equipment having common interface. 
In PC mode, this bi-directional sensor can be programmed and configured for: angle 
correction, smoothing time constants, measurements units and interface formats.

 

LCJ CAPTEURS - Z.A. le Chêne Ferré – 44120 VERTOU – France 

www.lcjcapteurs.com - Tel/ Fax : +33 (0)2 40 05 08 55 – [email protected] 

 

SARL au capital de 38112 € - APE : 7490B – SIRET 424 933 075 00022 

 

Robustesse  

 

Absence d’usure 

 

Insensibilité à l’effet gyroscopique 

 

Stabilité de la sensibilité aux vents faibles 

 

Prise au vent minimisée 

 

Effet de l’inclinaison sous le vent compensé

 

 

 

Robust 

 

No ageing 

 

Insensible to the gyroscopic effect 

 

Sensibility stability to light winds 

 

Minimum of resistance 

 

Compensation of inclination due to wind

 

Scale 1/1 

Содержание CV3F series

Страница 1: ...nal sensor can be programmed and configured for angle correction smoothing time constants measurements units and interface formats LCJ CAPTEURS Z A le Ch ne Ferr 44120 VERTOU France www lcjcapteurs co...

Страница 2: ...by the space Delivery contents CV7 sensor Support and clamp 25 m cable 4 conductors User s notice CV7 Software configuration Characteristics Numerical output signals NMEA0183 MWV XDR or specialised pr...

Страница 3: ...allation NMEA 0183 Interconnexions NX2 NEXUS or FI30 FURUNO WIND DATA Instrument interconnexions NX2 NEXUS or FI30 FURUNO SERVER Interconnexions FI50 Fi501 FURUNO Interconnexions CV7 configuration Pie...

Страница 4: ...ble red cable Connect the receiving display to the connector NMEA For a RS232 computer COM 1 entry Link NMEA to COM1 Rx Terminal 2 Link 0V to 0V the COM1 Terminal 5 If it s necessary link together the...

Страница 5: ...t NX2 or FI30 SERVER Interconnexions 12VDC 0V 1 2 1 2 3 4 NEXUS WIND LOG 12VDC 0V 1 2 Power source 12 VDC 10 to 14VDC with fusible Power source 0 V SCREEN 13 WHITE 14 YELLOW 15 GREEN 16 4 SERVER CV7 R...

Страница 6: ...reen Yellow Red Blue Power source 12 VDC 10 to 14VDC Red Black Power source 0 V FI 501 WIND NMEA 2000 NMEA 2000 12VDC OptFI50 interface CV7 Green Yellow Red Blue FI50 Dir1 Dir2 Speed V 0V FI50 Cable 2...

Страница 7: ...com Configuration_CV7 Realise the following connexions Red cable power Blue cable power Yellow cable Green cable Decompress the file in the directory of your choice copy the shortcut to the office Do...

Страница 8: ...Piercing gauge...

Отзывы: