Страница 2: ...about this product can be obtained from lci1 com support or by downloading the free myLCI app The app is available on iTunes for iPhone and iPad and also on Google Play for Android users iTunes iPhone and iPad are registered trademarks of Apple Inc Google Play and Android are trademarks of Google Inc For information on the assembly or individual components of this product please visit https suppor...

Страница 3: ...gree of difficulty operation and ability of the individual performing the instructions This manual cannot begin to plot out instructions for every possibility but provides the general instructions as necessary for effectively interfacing with the device product or system Failure to correctly follow the provided instructions may result in death serious personal injury severe product and or property...

Страница 4: ... Verify the battery is fully charged and hooked up to the electrical system 3 If equipped remove transit bars 4 Press and hold the IN OUT switch in the OUT position Fig 1A until the slide out is fully extended and stops moving 5 Release the switch which will lock the slide out into position Note Only hold the switch s OUT position until the slide out stops Retracting Slide Out 1 Verify the battery...

Страница 5: ...e The LCI Above Floor Slide out Vertical Motor system is designed to operate as a negative ground system A 12V DC system must maintain good wire connections It is important that the electrical components have good ground connection Over 90 of unit electrical problems are due to bad ground connections Mechanical Maintenance Although the LCI Above Floor Slide out Vertical Motor system is designed to...

Страница 6: ...or worn Replace gear drive assembly Teeth on inner rail broken and worn Replace inner rail assembly Troubleshooting The LCI Above Floor Slide out Vertical Motor system is only one of four inter related slide out system components These four components are Chassis Slide out room Unit LCI Above Floor Slide out Vertical Motor system Each component needs to function correctly with the others or misali...

Страница 7: ...ssuring a full 12V DC charge The following tests require only a DC voltmeter or DC test light and a jumper lead 1 Attach voltmeter or test light leads to the negative and positive switch terminals on back of the wall switch Does the meter indicate 12V DC A If yes go to step 2 B If no go to step 3 2 Check the incoming leads to 12V DC Does meter indicate 12V DC Note If necessary disconnect leads at ...

Страница 8: ...Failure to disconnect battery can cause electricity to back feed through the motor and cause serious damage to the system as well as voiding the warranty Before accessing the power unit make sure power to the system has been disconnected The slide out adjustment for syncing the LCI Above Floor Slide out is handled through the drive shaft Fig 2 To sync the slide out system do as follows 1 Access th...

Страница 9: ...sly removed step 2 1 4 20 bolt and locking nut Fig 6 to secure the synced slides Fig 5 Motor End Motor Drive Shaft Outer X Shaft Rotate X Shaft to Align Holes Outer X Shaft Lock Nut Hex Bolt Fig 6 5 Reconnect internal and external power to the unit 6 Using the switch Fig 1 operate the slide out system to make sure the drive and follow slides are properly synced 7 If slides remain out of sync repea...

Страница 10: ... as well as voiding the warranty 1 Before accessing the power unit make sure power to the system has been disconnected 2 Access the out stop assembly Fig 7 Out stops are located on the outer edge of the drive and follower rails Note The slide out out stop assembly will be accessible from the inside of the unit The slide out motor and mechanism are accessible from the outside 3 Using a 15 16 wrench...

Страница 11: ... the system to fail and void the limited warranty 4 When the slide out reaches its stop Fig 7 do NOT continue to manually extend or retract the slide out or damage to the system can occur Note Stops are factory set to optimize slide out extension retraction No additional adjustment to the stops should be needed If the retracted slide out does not fully seal then an adjustment to the in stops may b...

Страница 12: ...supplied Resettable Fuse Green Yellow Motor Wire Splices Red Black Wall Switch Motor and Drive Gears Battery Ground Splice Note Wire colors may differ when using a non Lippert Components switch Additional wiring MUST use 10 AWG minimum and conform to current RVIA electrical standards Auxiliary Battery ...

Страница 13: ...Rev 11 27 19 Page 13 CCD 0002711 Notes ...

Страница 14: ...resentative has been provided Any unauthorized use shall void any applicable warranty The information contained in this manual is subject to change without notice and at the sole discretion of LCI Revised editions are available for free download from lci1 com Please recycle all obsolete materials For all concerns or questions please contact Lippert Components Inc Ph 574 537 8900 Web lci1 com Email...