PCSS-F Additions Technical Manual
LS-CS-M-023
Page 4-24
Original Language Version:
1.02
Released:
03/12/2013
X03
X04
X05
X06
X07
FIO04
–
CN4
1
2
3
4
5
X08
6
X09
7
Y06
8
0VDC
9
Y07
0VDC
P03
10
11
12
P04
13
24VDC
14
Station 1 Indicator
Station 2 Indicator
Figure 4-21: Error Reset Option 4 (CN4
-
FIO04 Output Connections)
This error reset option is intended for use with down switch options allowing two operator
stations. The error reset function is only active on the active station. The active station is
indicated by a light mounted on each station.
4.3.1.1
Option Selection
To select error reset option 4 during the PCSS configuration, set the initial value for the error
reset option selection variable to
4
. This will ensure that this option is initialised with all
required inputs activated when the PCSS software is started.
4.3.2
Error Reset Option 5
X03
X04
X05
X06
X07
FIO04
–
CN4
1
2
3
4
5
X08
6
X09
7
Y06
8
0VDC
9
Y07
0VDC
P03
10
11
12
P04
13
24VDC
14
Error Reset 1
Error Reset 2
Figure 4-22: Error Reset Option 5 (CN4 - FIO04 Input Connections)
This error reset option is intended for use with down switch options allowing two operator
stations. The error reset function is only active on the active station.
4.3.2.1
Option Selection
To select error reset option 5 during the PCSS configuration, set the initial value for the error
reset option selection variable to
5
. This will ensure that this option is initialised with all required
inputs activated when the PCSS software is started.