E l e c t r i c a l S p e c i f i c a t i o n s
Important –
Qualified and licensed electricians must perform all
electrical hookups. The following specifications must be followed in
order to ensure proper performance and safety.
WARNING:
Starting an incorrectly wired spa could cause severe
damage to the mechanical equipment or even
bodily harm. Have your licensed electrician verify
GFCI (or RCD) wiring with the schematics on pages
9-13 prior to starting the spa or call the technical
support line at 866-461-3123.
Caution:
Failure to abide by specifications listed may result in
damage to the equipment and will void the warranty.
All spas must be wired with a 50 Amp breaker (or according to IEE
wire regulations for export models). Failure to do so will cause
equipment damage and will not be covered under your warranty.
All spas must be protected with an over current protective device
with built-in GFCI (or RCD for export models) in the service panel.
Volts
(V)
Freq.
(Hz)
Phase
Rating
(A)
GFCI
(A)
Wire size from GFCI
to Main Panel
*†
# of
Terminals
on plug
240
60
1
40
50
6-3 plus ground (up to 130’)
4-3 plus ground (up to 230’)
2-3 plus ground (up to 360’)
4
230
50
1
32
IEE wire
regulation
3x4 mm
2
4
230
50
2
16
IEE wire
regulation
5x1.5mm
2
5
230
50
3
16
IEE wire
regulation
5x1.5mm
2
5
WARNING:
Disconnect the electrical power before servicing.
Before obtaining access to terminals, all supply
circuits must be disconnected.
Caution:
Test the GFCI (or RCD) before each use of the spa.
*
Solid copper
†
Wire size may need to be reduced at GFCI to fit into the breaker
Содержание Limited 1304
Страница 13: ...11 European 1x32A Wiring Diagram See wire size table on page 8 Jumper L1 L2 L3...
Страница 14: ...12 European 2x16A Wiring Diagram See wire size table on page 8 Jumper L2 L3...
Страница 15: ...13 European 3x16A Wiring Diagram See wire size table on page 8 No Jumper...
Страница 46: ...44 Notes...
Страница 48: ...La Z Boy Spas 11638 54th Street North Clearwater FL 33760 866 461 3123 www lazboylimitedspa com...