POWER CORE User Manual
Version: V6.0.0/5
366/459
19. Networking POWER CORE
19.3
Remote Control of Sources (via Ember+)
If the system has been configured as an
, then it can publish parameters from any Source or
Summing Bus to the network as follows.
On the Ember+ Provider
1.
Select the "Source" or "Sum Bus" element and define the
Ember+Local Provider Nr
- for example,
select
1
to publish all available source parameters via
Local Provider 1
:
The published parameters include:
·
Type & Mode Information
·
Fader Functionality
·
DSP Functionality
·
Aux Bus Functionality
By assigning different provider numbers to different Source and Sum Bus elements, you can control certain
sources from external device 1, others from device 2 and so on.
2.
Edit the
Display
name as required - all Sources and Sum Buses published to the Ember+ network must
have a unique
Display
name.
On the Ember+ Consumer
Published Source or Sum Bus parameters appear under the
Source
or
Sum Bus
branches of the Ember+
provider tree. The branch number represents the Source/Sum bus number (defined by the provider's configuration);
the ID string corresponds to the Source/Sum Bus name.
Note that you cannot see Sources or Sum Busses which have not been published (by the provider), and each
Source/Sum Bus can only be assigned to one provider exclusively.