Chapter 2: Installation
System Connections
GPI Inputs
The GPI inputs are opto-couplers; accept voltages of 3V..20V; draw a typical current of 8 mA; and are floating and
galvanically isolated.
Ø
GPI 1
·
GENERAL PURPOSE IN 1 & 2
– used for project-specific applications, please check your system
specification for details.
·
ROUTER TAKEOVER (IN)
– use this input to force a takeover to the
Router Module. The
takeover is triggered by a positive edge at the input.
·
PREPARE COLDSTART (IN)
– when turning on the Nova73, supply a voltage at this input to force a
Ø
GPI 2
·
ALARM IN 1 to 4
- can be used to monitor peripheral equipment such as devices from other
manufacturers. The inputs
MUST
be factory-configured. Each alarm is triggered by an applied voltage.
When the input is open or grounded, the alarm is cancelled. Within the AdminHD configuration, you can
assign a text error message for each input, and define whether the input activates the
Predefined standards are:
o
ALARM 1 IN
= failure of the external clock supply (activates the global alarm).
o
ALARM 2 IN
= failure of the external power supply (activates the global alarm).
o
ALARM 3 IN
= failure of the external I/O system (activates the global alarm).
o
ALARM 4 IN
= the external device exceeds its operating temperature (activates the global alarm).
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...