Chapter 6: Trouble-shooting
The network connection to the control system is not working
The network connection to the control system is not working
If you cannot establish network communication between your computer and the control system:
1.
Check the
of your computer's network interface card.
2.
If applicable, check that the software you are running is
2
system. When
connecting from mxGUI or AdminHD, the first three digits of the software versions
must
match.
3.
Try a
to test whether you have a valid network connection:
·
If the ping test fails, then there is something wrong with your network configuration.
·
If the ping test is successful, then this confirms that the network communication is working. If you still
cannot connect to the mc²56 MKII control system, then something on your computer is blocking the
network connection. Try disabling any firewall and/or antivirus software.