background image

mc²36 MKII Installation & Service Guide

Version: 1.0/1

34/56

5. Service Procedures

5.2

Restarting a Bayserver or Gateserver

Each bay has its own Ethernet server which can be restarted from the front panel. The procedure is the same
for  Bayservers  (in  channel  bays)  and  the  Gateserver  (in  the  centre  section).  Note  that  if  you  restart  the
Gateserver, then this will affect the whole console.

You should perform this procedure if the graphics on an individual display freeze or look odd. Or, if the controls
and indicators on a panel do not respond or update. These symptoms can sometimes occur if the server looses
its Ethernet connection to the mc

2

 control system. 

1.

Using a pointed object, press the recessed button at the top of the display:

The  server  restarts  in  a  few  seconds;  during  this  time  you  will  see  the  boot-up  screen  on  the  display.  Once
complete, communication with the control system is re-established, and the Channel Display (or Central GUI) is
reinstated.

Содержание mc236 MKII

Страница 1: ...mc 36 MKII Installation Service Guide Version 1 0 1 To obtain the latest documentation and software downloads please visit Edition 28 April 2021 www lawo com lawo downloads...

Страница 2: ...ers It cannot be guaranteed that all product names products trademarks requisitions regulations guidelines specifications and norms are free from trade mark rights of third parties All entries in this...

Страница 3: ...stallation 15 Unpacking 15 4 1 Packing List 15 4 2 Mounting the Frame 16 4 3 Dimensions and Weight 16 4 4 Temperature and Cooling 16 4 5 Minimum Distances for Control Surface Mounting 17 4 6 Installin...

Страница 4: ...g a TFT Display 40 5 6 Bayserver Gateserver Switch Settings 41 5 7 Replacing a Console Power Supply 43 5 8 Replacing the Local IO 45 5 9 Replacing the Network Switch 47 5 10 Replacing the A__UHD Core...

Страница 5: ...ion Tips useful tips and short cuts Attention alert you when an action should always be observed Further Information Mechanical drawings and data sheets including weights and dimensions are available...

Страница 6: ...rve all of the instructions provided in the General Safety Information for Lawo Equipment booklet delivered with your devices Double click here to open the same information as a pdf Please also observ...

Страница 7: ...me sizes 16 or 32 fader Both variants include a central bay with 16 faders To make the 32 fader variant a single channel bay is added This adds 510 mm to the width of the console Note that you cannot...

Страница 8: ...n be ordered for either Studio or OB Van Mobile mounting The Studio version comes with wider side panels and is ready for table top mounting The OB Van version is fitted with narrow aluminum side plat...

Страница 9: ...VB 976 15 A full height blanking panel for the overbridge 1 x Central Panel 976 20 with 16 x 100mm motorised faders 43 rotary encoders 14 mini TFT displays 240 push buttons 1 XLR connector 1 USB port...

Страница 10: ...der Panel 976 10 with 16 x 100mm motorised faders 33 rotary encoders 8 mini TFT displays 177 push buttons 3 5 2 Ethernet Bayserver Internally each channel bay is fitted with an Ethernet Bayserver moun...

Страница 11: ...e Version 1 0 1 11 56 3 The Hardware 3 6 Overbridge Options The space to the right of the Central GUI is fitted with a full height blanking panel 976 15 This provides a general utility space to mount...

Страница 12: ...1 2 The MAINS 1 MAINS 2 connectors supply AC mains power to the frame The sticker states the AC mains requirements 4 CASE The CASE grounding screw M5 x 12mm should be used to ground the frame 5 A__UHD...

Страница 13: ...Ethernet server mounted inside the frame either a Bayserver in channel bays or Gateserver in the centre section The connections are made using both USB and Display Port In the centre section there is...

Страница 14: ...t redundancy 3 8 1 Additional Notes for the Gateserver The Gateserver provides a more sophisticated computing engine that can boot on its own once power is supplied to the control surface To achieve t...

Страница 15: ...local Lawo representative or email support lawo com 4 2 Packing List Included The following items are included with the control surface in the Accessories box 2 x 2m IEC power cables country specific...

Страница 16: ...ons and weight vary depending on the frame variant and control panel options Mechanical drawings and data sheets for all frame variants are available from the Downloads area at www lawo com after Logi...

Страница 17: ...he control surface when it is needed Usually it is connected to one of the USB ports on the front buffer below the centre section arm rest A suitable cable is provided Take care to connect the keyboar...

Страница 18: ...n not required Please note that there is no locking mechanism to anchor the script tray to the console and so it must be removed for transportation When fitted the tray glides to the left or right The...

Страница 19: ...s essential for operation the second provides redundancy CLOCK IN OUT external synchronization AES3 MIC LINE MADI GPIO audio and GPIO breakouts for the local IO MGMT A B control data to from the Manag...

Страница 20: ...rovides a summary AC Mains Requirements sticker 4 10 3 Mains Connections The MAINS connectors are located on the frame s rear panel There are two connectors one for each of the internal supplies For r...

Страница 21: ...l ground for EMC reasons 1 Fasten the grounding cable to the rear of the frame using the CASE grounding screw M5 x 12mm The control surface must be on the same potential as all other system devices mo...

Страница 22: ...etwork Lawo may deliver a suitable network switch with the system This could be replaced by any other suitable switch fabric that provides comparable performance You must use a network switch and NOT...

Страница 23: ...x XLR male 8 x AES3 IN wired to 8 x XLR female 8 x AES3 OUT wired to 8 x XLR male 1 x 64 channel MADI available via SFP To use this port you must fit a Lawo certified SFP module 8 x GPIO wired to 1 x...

Страница 24: ...gable and so they can be fitted or exchanged while the device is powered 1 Remove the dust caps from both the port and SFP module Store these carefully so that they can be replaced if a module is remo...

Страница 25: ...ock signal is available to all streaming ports 4 14 1 Audio over IP Specification Each pair of I O ports provides RAVENNA multi channel digital audio over IP Up to 256 bi directional channels at 48kHz...

Страница 26: ...tor Type RAVENNA RJ45 Kit 976 70 2x SFP 100 1000Base T RJ45 2x CAT6 Cable 1m 2x Neutrik NE8FDX P6 B Neutrik etherCON RAVENNA MM Fiber Kit 976 71 2x SFP 850nm MM 7dBm 1000 Base 2x MMF Cable LC LC 1m 2x...

Страница 27: ...ng with 1 2 Preparation Each IO connection kit comes as a bundle containing 2 x SFP modules 2 x interconnecting cables to connect the SFP modules to the connectors 2 x rear panel connectors Labeling n...

Страница 28: ...nel It is best to stand behind the console frame as shown View from above 2 Gently tilt the unit forwards and remove the RJ45 connector on the back of the panel 3 Carefully remove the Overbridge blank...

Страница 29: ...stowed in a safe place for future use You are now ready to fit the new connector kit which you assembled earlier 6 Starting with the SFP module end thread the first cable into the console through the...

Страница 30: ...e fixed in place using the cable raceways Take care not to bend the cables by laying sufficient loops as shown Inside Console Frame SFPs Cables correctly installed The SFP slots are numbered as shown...

Страница 31: ...ort Rear Connector Panel with covers stickers 4 15 External Synchronization Console Rear Panel The CLOCK IN can be used to connect an external sync reference The input accepts Wordclock only When runn...

Страница 32: ...implementation 1 x Stereo Phones This stereo phones output can be used to connect a pair of stereo headphones The socket is wired from the Headphone 1 output which by default follows the CRM 1 source...

Страница 33: ...casing shields etc the device MUST be switched off and disconnected from the mains supply Check the unit for electrical safety after completing the work Using the Service Instructions We recommend th...

Страница 34: ...ole You should perform this procedure if the graphics on an individual display freeze or look odd Or if the controls and indicators on a panel do not respond or update These symptoms can sometimes occ...

Страница 35: ...ds DO NOT attempt to open the frame without first disconnecting the mains supply 1 Remove the screws at the bottom of the panel using a T20 Torx driver The number of screws vary depending on the panel...

Страница 36: ...k XLR and USB port 5 Carefully remove the panel by lifting it out of the frame Lay it it face down on a piece of foam or similar ESD proof protective material away from the console 6 Check that the ro...

Страница 37: ...n the frame without first disconnecting the mains supply 1 Follow the previous section s steps to lift the panel you will see the Hood Fastener stowed safely within the frame 2 Release the fastener fr...

Страница 38: ...open the frame without first disconnecting the mains supply 1 Remove the panel from the console frame as described earlier and lay it it face down on a piece of foam or similar ESD proof protective ma...

Страница 39: ...it helps to support it from behind as you turn the panel You are now ready to fit the replacement 7 Insert the new fader unit into position 8 Carefully lift the panel onto its side supporting the fad...

Страница 40: ...be long enough to turn the countersunk screws without scratching the front panel If you attempt to use a short driver or driver attachment damage can occur 2 Remove the connectors taking note of where...

Страница 41: ...ON Central GUI OFF Channel Display S1 DIP Switch 3 5 6 7 8 are unused and should be set to OFF SW1 Rotary Switch Address sets the bay index counted from left to right in two s as viewed from the front...

Страница 42: ...l in the bay you wish to adjust as described earlier and secure it in place using the Hood Fastener As soon as you lift the panel you will see the Bayserver mounted inside the frame Note that you do n...

Страница 43: ...elease the plug You must remove the MAINS connectors from the frame rather than from the wall as the IEC sockets form part of the PSU module If you do not then the PSU module will get stuck during ste...

Страница 44: ...T to drop any nuts or washers into the desk 8 Remove the PSU block from the frame 9 Now fit the replacement and secure using the five hex nuts shown in step 7 10 Replace the power signal and grounding...

Страница 45: ...nel and remove the Central Panel Central GUI display and Overbridge blanking panel DO NOT attempt to open the frame without first disconnecting the mains supply 1 Disconnect all of the local IO cablin...

Страница 46: ...crews three on each side holding the unit in place Remove all of the screws using a T20 Torx driver 5 Carefully remove the unit by sliding it out of the rear of the console frame Take care that the fr...

Страница 47: ...frame without first disconnecting the mains supply 1 Remove the Central Panel Central GUI display and Overbridge blanking panel as described earlier See Replacing a Panel and Replacing a TFT Display...

Страница 48: ...d that the cables do not get caught 5 Slide the replacement unit into the console frame taking care not to scratch the unit or get any cables caught underneath Tighten the nuts to hold the unit in pla...

Страница 49: ...tion data so that the current configuration can be reinstated To replace the core you will need to lift the Central Panel DO NOT attempt to open the frame without first disconnecting the mains supply...

Страница 50: ...t You are now ready to fit the replacement 5 Position the new unit into the frame taking care not to scratch the unit or get any cables caught underneath Tighten the five hex nuts to hold the unit in...

Страница 51: ...nels 976 61 Control Surface Modules Fader FC Panel 976 10 Central Panel 976 20 Channel Display 977 13 Overbridge Blanking Panel 976 15 Internal Components System Core 976 30 Local IO 976 35 PSU Block...

Страница 52: ...ch control surface variant In each case double click on a link to open the diagram as a pdf 16 Fader OB Van 16 Fader Studio 32 Fader OB Van 32 Fader Studio 6 3 Wiring Diagrams The following diagrams s...

Страница 53: ...er a high pass filter and 20dB PAD The maximum analog input level with the PAD enabled is 24dBu 6 4 2 Talkback TB 3 pin XLR connector male This connector is wired from the 3 pin female XLR Talkback co...

Страница 54: ...ons conform to the stereo AES3 standard 6 4 6 MADI The console s MADI interface conforms to AES 10 and supports up to 64 bi directional channels at 48kHz or 32 channels at 96kHz To use the interface y...

Страница 55: ...mc 36 MKII Installation Service Guide Version 1 0 1 55 56 6 Appendices 6 4 7 GPIO 37 pin D type connector DB37 female 6 4 8 Headphones 6 35mm stereo jack connector...

Страница 56: ...taken from path 2 And vice versa The result is that the receiver can switch from one path to the other without impacting upon the stream content The network class determines how much delay between the...

Отзывы: