11. The RAVENNA Web UI
11.13
Creating SMPTE 2022-7 Compatible Streams
To support
(streaming redundancy), a stream must be transmitted and received via two separate
network paths.
For an A__line device, the TX or RX interfaces are ETHERNET A (ra0) + ETHERNET B (ra1).
TX Stream Properties
First, open a RAVENNA Web UI connection to the sending device and make sure that the 'TX Stream Properties'
are configured to use both RAVENNA interfaces. This means assigning a multicast IP address to both of the
ra0
and
ra1
fields:
ra1 - define multicast IP address
Both ra0 and ra1 should be set to auto
All other properties should be configured as for a non-redundant stream, see
Once you click
Apply
, the TX stream will be duplicated and published separately via both interfaces. Note that
information about both streams (main and redundant) is contained in the same SDP information.