Technical support maintenance manual
Rel. 0.00 / February 2020
28
12.4. DISASSEMBLING THE PUMP
Warning
Wait for the boiler to cool off before performing these operations. DANGER OF BURNS.
Figure A
: cut the CLAMP of the
high pressure SILICONE PIPE
and remove the PIPE.
Warning
Be careful not to tear the pipe. While reassembling, the CLAMP must be
replaced and tightened with the OETIKER PLIERS.
Figure B
: disconnect the PUMP
THERMAL PROTECTION (
1
) and
the two electrical connections in-
dicated (
2
).
Figure C
: remove the EP5GW/
EVO 230V PIPE from the top bra-
cket (
3
) and extract it from the
machine while also removing the
LOWER BRACKET (
4
).
Then remove the LOWER BRA-
CKET and disconnect the SILICO-
NE PIPE (
5
).
A
H
N
B
1
2
2
3
C
4
5