Technical support maintenance manual
Rel. 0.00 / February 2020
15
BLUETOOTH
INFORMATION
MAC address:
xxx
Firmware:
xxx
Connected:
No
Please press key
Press the MULTIFUNCTION button to return to the sub-
menu.
7.2.2.6. SERVICE
Perform unit operation tests and list of errors reported.
Test Mainboard
Test the operation of the electronic board.
Note
Use the ▲ ▼ scroll arrows to view the 9 test screens.
•
Screen 1/9
Screen 1 displays the software version of the board.
VERSION
1/9
xxxxxxxxxxx
Build-Information
xxx x xxxx
xxxxxxx
•
Screen 2/9
Screen 2 displays the status of the:
- flow sensor
- water level sensor
- capsule tray sensor
- capsule loading lever sensor
INPUTS 1
2/9
Flow
ON
Water
-
Tray
IN
Lever
CLOSE
The “
Flow
” sensor indicates the pulses of the volumet-
ric metering device.
The “
Water
” sensor indicates the presence of water in
the water tank.
The “
Tray
” sensor indicates the presence or absence of
a capsule tray.
The “
Lever
” sensor indicates the opening or closing of
the capsule loading lever.
•
Screen 3/9
Screen 3 displays the values of the analogue inputs.
INPUTS 2
3/9
3V
xxx
5V
xxx
22V
xxx
NTC
xxx
VAC
xxx
Freq
xxx
Parameter “
3V
” indicates the value of voltage in milli-
volts (mV) of the Micro Controller Unit.
Parameter “
5V
” indicates the value of voltage (mV) of
external switches.
Parameter “
22V
” indicates the value of voltage (mV) of
the ceramic milk valve.
Sensor “
NTC
” indicates the temp. of the heater.
Parameter “
VAC
” indicates the voltage value.
Parameter “
Freq
” indicates the frequency value.
•
Screen 4/9
Screen 4 displays the various positions and parameters
of the ceramic valve.
Содержание blue LB 1200 USA CLASSY PRO 120V
Страница 1: ...LB 1200 USA CLASSY PRO 120V TECHNICAL SUPPORT MAINTENANCE MANUAL ...
Страница 54: ......