- 9 -
SERVICE CONNECTOR
ETHERNET, CANOPEN, SERIAL INTERFACE AND ANALOG OUTPUT
Instrument model
LCBRS485 - LCBRS485ANA - LCBCANOPEN -
LCBETHERCAT - LCBETHEIP - LCBMODBUSTCP -
LCBPOWERLINK - LCBPROFINETIO - LCBSERCOIII
Male M12,
8 pin, A-coded
1 +SUPPLY (12/24 VDC)
2 -SUPPLY (GND)/INPUT COMMON
3 INPUT No. 1
4 INPUT No. 2
5 OUTPUT COMMON
6 OUTPUT No. 1
7 OUTPUT No. 2
8 OUTPUT No. 3
-
It is recommended to ground the power supply
negative pole.
1
2
3
4
5
6
7
8
INSTRUMEN
T
OUTPUTS
max 115 VAC 150 mA
INPUTS
supply 5÷24 VDC
12/24 VDC SUPPLY
+
-
+