background image

M A N U A L   F O R   U S E   A N D   M A I N T E N A N C E

S 3
S U P E R   3 0 0 0
N E W
R A P I D
S P A Z I O

LSC 001 REV. 00

Содержание NEW

Страница 1: ...M A N U A L F O R U S E A N D M A I N T E N A N C E S 3 S U P E R 3 0 0 0 N E W R A P I D S P A Z I O LSC 001 REV 00...

Страница 2: ...MANUAL FOR USE AND MAINTENANCE 2 LSC 001 REV 00...

Страница 3: ...STARTING AND SETTING OF THE APPLIANCE Range New Rapid Spazio Super 3000 S3 EK EP Models page 7 2 1 STARTING 7 2 2 ALARMS DESCRIPTION 10 2 3 REGULAR MAINTENANCE OF THE EQUIPMENT MADE BY THE USER 13 Cha...

Страница 4: ...nstaller is not allowed to modify the existing system pre arranged by the customer See the chapter 1 5 Arrangements for installation made by the customer WARNING The appliance must be installed where...

Страница 5: ...d 40 C The use of any electrical appliance requires observance of the following important rules Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefooted Do not pul...

Страница 6: ...nected to the electric mains and so it is necessary to pre arrange a single pole switch with opening of contacts equal or superior to 3mm according to regulations in force pict 1 The drain pipe of the...

Страница 7: ...on the switch of the machine 3 moving it to position ON 1 and checking that the electric connection control light where present turns on N B According to the water quantity which has been manually fil...

Страница 8: ...p and press it to start the delivery Once you obtain the desired coffee quantity in the cup manually stop the delivery pressing the same button f For Seletron and Ek model press any of the coffee deli...

Страница 9: ...on 2 To switch it off move it back to position 1 WARNING It is allowed to place cups on the upper grid of the machine 14 as long as the cups have their hollow part upwards pict 2 This is in order to a...

Страница 10: ...king alarms LOSS OF DATA This is not a blocking one It signals that because of external causes the control board has lost the data set by the installer therefore it is now operating with standard defa...

Страница 11: ...c feeding system has to be checked by qualified personnel This alarm automatically disappears when the power is back within the proper range The proper operating range of the feeding power goes betwee...

Страница 12: ...ry is blinking after 5 seconds This alarm is a blocking one and is visualized when during a coffee delivery there is a malfunction of the flowmeter relating to the group having the delivery or if the...

Страница 13: ...lockwise the hot water knob 6 until you empty the boiler completely checking the sight glass water level indicator 2 and then refill immediately the boiler using the manual filling valve 1 1b To regen...

Страница 14: ...s are clean Then reassemble them following the sequence shown in pict 3 WARNING Every day after daily work and cleaning turn off the electric switch of the system the water supply tap and gas supply t...

Страница 15: ...s been manually refilled one can program the automatic filler up system to operate when the switch is turned on 3 until the proper water level in the boiler for standard operation has been reached HEA...

Страница 16: ...the blinking YY using the buttons and confirming with the button automatically you go back to the main visualization status on the display COFFEE BREWING a Remove a filterholder 11aor 11b according if...

Страница 17: ...e display 33 Press the same button to switch it off 24 TIMER FUNCTION The appliance can be programmed so as to have its switching ON OFF at preset time for each day of the week To program the switchin...

Страница 18: ...ly increased thus repeat the operations indicated from 4 to 8 to set the switching ON and OFF time of the appliance for the remaining days At the end of the programming phase of the weekly TIMER soon...

Страница 19: ...et the datum relating to partial counters starting from zero again you have to press and keep pressed the button for about 2 seconds until the display shows the writing Reset 3 Press the button to res...

Страница 20: ...the display shows where the symbol is fixed and indicates the total number of hot water deliveries made by the appliance N B Perpetual counter which cannot be put at zero N B If the appliance is run...

Страница 21: ...entre HIGH TEMPERATURE This alarm is not a blocking one It appears when the main running program of the appliance recognizes a temperature boiler value which is higher of 5 C than the preset temperatu...

Страница 22: ...corresponding to one of the brewing groups is longer than the value which has been preset in the relating menu DAMAGED COUNTER This is not a blocking alarm It appears when the main running program of...

Страница 23: ...pills Press and keep pressed the hot water push button 6 for 3 seconds the automatic emptying out process of the boiler starts in this phase all the controls of the machine are not enabled At the end...

Страница 24: ...I K E L E T T R I K E L E T T R I K E L E T T R I K E L E T T R I K SUPER 3000 1 2 SET 9 012 11 b 17 4 8 5 12 b 16 11 a 14 8 10 41 16 12 6 7 5 30 31 1 2 41 3 15 5 SUPER 3000 1 2 SET 9 14 10 013 11 a...

Страница 25: ...7 8 9 15 4 3 12 2 10 16 11 a 1 019 16 14 12 12 5 8 10 15 4 17 3 9 6 7 1 2 11 a 11 b 018 16 14 12 12 12 5 8 10 15 4 17 3 41 9 1 31 30 6 7 5 2 8 11 a 11 a 11 b 021 O F F O N NEW EC O N O F F 25 26 27 2...

Страница 26: ...MANUAL FOR USE AND MAINTENANCE 26 LSC 001 REV 00 5 5 6 8 11b 3 7 15 1 2 8 14 11a 12b 12b 16 9 10 23 24 22 17 13 022 12b 12b 4 S3 EP...

Страница 27: ...MANUAL FOR USE AND MAINTENANCE LSC 001 REV 00 27 5 5 6 8 11b 3 7 15 1 2 8 12 14 12 11a 25 27 28 29 26 25 27 28 29 26 16 9 10 18 19 20 21 22 23 24 17 4 13 023 S3 EK...

Страница 28: ...MANUAL FOR USE AND MAINTENANCE 28 LSC 001 REV 00 S3 Seletron 8 11b 3 7 15 1 2 8 11a 25 27 28 29 26 25 27 28 29 26 9 10 024 33 38 37 40 39 24 5 5 6 12 14 12 16 13 17 4 23...

Страница 29: ...right LED for 2nd group on the right LED for 1st group on the right Control light machine on Led for cup warmer status Electric cup warmer operating button 1 short coffee preset delivery button 1 long...

Страница 30: ...MANUAL FOR USE AND MAINTENANCE 30 LSC 001 REV 00 10 03 Realized by STUDIO 80 Bologna Italy...

Страница 31: ...MANUAL FOR USE AND MAINTENANCE LSC 001 REV 00 31...

Страница 32: ...La Spaziale S p A Via E Duse 8 40033 Casalecchio di Reno Bologna Italy Tel 39 051 611 10 11 Fax 39 051 611 10 40 E mail info laspaziale com Web Site www laspaziale com...

Отзывы: