LaserPoint Fit IPL-R Скачать руководство пользователя страница 1

LaserPoint srl   -   Fit IPL-R Instruction Manual   -   page 1 

 

 

 

Fit IPL-R 

Instruction Manual 

(Rev06 - Jun 2018; Firm. Vers.11) 

 

LaserPoint srl - Via Burona, 51 - 20090 Vimodrone (Milano) - Italy 

Phone +39 02 27 40 02 36 - T39 02 25 02 91 61 

www.laserpoint.eu

     

 

WARNING! The user of this instrument must be trained to the use 
of power lasers and associated risks. LaserPoint is in no way liable 
for  any  damage  resulting  from  improper,  careless  or  above  rated 
limits use of this instrument. 

                                                                                                                                   

  

Содержание Fit IPL-R

Страница 1: ...urona 51 20090 Vimodrone Milano Italy Phone 39 02 27 40 02 36 Telefax 39 02 25 02 91 61 www laserpoint eu WARNING The user of this instrument must be trained to the use of power lasers and associated risks LaserPoint is in no way liable for any damage resulting from improper careless or above rated limits use of this instrument ...

Страница 2: ...trial Standard Description Performance Criteria EN 55022 1994 amendment 1 1995 amendment 2 1997 Limits and methods of measurement of radio interference characteristics of information technology equipment Classe B EN 61000 4 2 1995 Electromagnetic compatibility EMC Part 4 Testing and measurements techniques Section 4 2 Electrostatic discharge Classe B EN 61000 4 4 1995 Electromagnetic compatibility...

Страница 3: ...of this instrument can be matched by user to a custom own reference by means of the instructions reported at Paragraph n 11 of the Operation Section of this Manual Operation Section 1 Safety Take all the required safety procedures needed when working with high power light sources and wear protection glasses all the time The beam must hit ONLY the sensor head front side Avoid to incidentally expose...

Страница 4: ...ore starting the first measurement or a new one the instrument has to be reset to do so just push and soon release the ON Zero button After the LCD has displayed CAL the lateral LED turns steady green and FIT blinks Any previously recorded value is zeroed and the instrument is ready to measure An automatic Zero is performed by Fit after every measurement 6 Measurement Cycle Check that the light be...

Страница 5: ...he beam stop Avoid taking measurements during the machine warm up or in case of beam instabilities Always position and keep the beam in the centre of detector The measurement starts automatically during the measurement the display shows tr d During the acquisition time the LED blinks green The bar graph indicates the head temperature on an arbitrary scale 10 Measurement Display As soon as the meas...

Страница 6: ...he battery life the instrument automatically switches off after 5 minutes of stand by operation However the last recorded value is not lost to retrieve it go back to Paragraph 2 and follow the instructions After the internal auto check cycle the display will show the last measured value To intentionally shut the instrument off keep the ON Zero button pushed until the LCD shuts off this takes appro...

Страница 7: ...hout cost to yourself It is emphasised that this no cost return option is only available when you purchase a new product of equivalent type that fulfils the same function Please inform your supplier of your wish to have the old instrument collected when ordering the replacement If you wish to dispose of the instrument without replacing it then the appliance must not be mixed with unsorted municipa...

Страница 8: ...ttery replacement h 200 Operating temperature range C da 10 a 40 Storage temperature range C da 10 a 60 Weight body g 336 Weight sensor with cable g 178 Size head LxWxH mm 60x100x26 Size body LxWxH mm 95x71x46 Specifications subject to change without notice 1 Individually compared against a NIST or PTB reference Warranty All Laser Point instruments are warranted against defect in material and work...

Отзывы: