ICS-KP12 Instruction Manual
00517-53-000
Issue 3 15 January 2020
LASERMET
ICS-KP12
INSTRUCTION MANUAL
ACCESS KEYPAD WITH
FAIL-SAFE OVERRIDE TIMER
Issue 3
Страница 1: ...ICS KP12 Instruction Manual 00517 53 000 Issue 3 15 January 2020 LASERMET ICS KP12 INSTRUCTION MANUAL ACCESS KEYPAD WITH FAIL SAFE OVERRIDE TIMER Issue 3 ...
Страница 2: ...ation 5 3 1 Positioning 5 4 Wiring 7 4 1 Connecting to Lasermet ICS Control Panels 8 4 2 Connecting to Door Lock 8 4 3 Connecting two or more Keypads to one ICS 10 5 Fixing 11 5 1 Attaching the Keypad to the Backplate 11 5 2 Removing the Keypad from the Wall 11 6 Programming 12 7 LED Indicators 14 8 Operation 15 8 1 Default Settings 15 9 Specifications 16 10 Warranty 16 11 Contact Details 17 ...
Страница 3: ...to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imperative that ...
Страница 4: ... should the programmed time function fail the override will still cease after around 30 45 seconds restoring the full protection of the interlock system Lasermet provides a full range of laser interlock equipment including control systems interlock switches illuminated warning signs laser shutters door locks external power supplies etc which can be connected to provide a complete laser interlock s...
Страница 5: ...nvenient position for use and wiring Normally it is located on the outside safe side of the entry door of the controlled area on the wall adjacent to the door handle approximately 1 2m up from floor level During installation wired connections will need to be made from the ICS KP12 to the Interlock Control System and possibly the magnetic door lock and allowance should be made for the installation ...
Страница 6: ... may be used as a marking template If using a round conduit box the holes will align with the cover fixing holes Once all the holes have been made secure the wall plate and the locking plate as shown in Figure 1 with the plastic wall plate against the wall Check that the plastic wall plate and locking plate are aligned as shown Feed the cables through the hole in the centre of the locking plate NO...
Страница 7: ... the 24V terminal and the negative to the 0V terminal The REM input can be connected to a separate pushbutton switch to activate the keypad remotely When the button is pressed the keypad activates its outputs according to the programmed settings as though the correct code had been entered on the keypad The pushbutton is wired between the REM and 24V terminals If this function is not required simpl...
Страница 8: ...de attach the keypad to the wall plate as described later in this manual 4 2 Connecting to Door Lock The ICS KP12 has a relay for releasing electric door locks The relay is rated at 6A resistive load This is normally sufficient for two magnetic door locks Note that magnetic door locks must be fitted with suppression diodes and must be connected the right way round Magnetic door locks supplied by L...
Страница 9: ...ICS KP12 Instruction Manual 00517 53 000 Page 9 of 17 Issue 3 15 January 2020 Figure 3 ICS Wiring Diagram ...
Страница 10: ...controlled area through more than one door while the laser is on additional keypads may be connected as required In this case to prevent all the doors being released at once when an exit button is pressed the REM connection from each keypad is not wired back to the ICS but just wired to the exit button for the relevant door Figure 5 Connecting two Keypads to one ICS ...
Страница 11: ... Wall Once the keypad has been locked to the wall a 5mm flat screwdriver is required to release the locking latch before it can be removed Ensure that the supply is turned off Insert the screwdriver into the recess in the bottom of the keypad at the back and push the latch upwards to disengage it from the case Note that the latch is quite secure and some force may be needed before it releases When...
Страница 12: ...e of the following choices by pressing the appropriate key on the keypad Change User Code Change Program Code Change Override Time Change Door Unlocked Time Enter Test Mode Exit and return to normal operation 1 Change User Code 2 Change Program Code When you have selected one of these the PRG light will flash quickly to show that the keypad is ready to accept the new code Type in the new four digi...
Страница 13: ...ish to disable the selected output for example to disable the Door Unlock output because there is no door lock simply program the selected time to 0 seconds If you make an invalid entry e g by entering a time greater than 30 seconds the keypad will return to the Program Mode menu with the PRG LED flashing slowly and the time value will not be changed 5 Enter Test Mode Selecting this option causes ...
Страница 14: ...en the correct user code has been entered and the Door Unlock output is active The keypad has an audible alarm which sounds while the door is unlocked OVERRIDE ON This message appears in red in the lower black panel when the correct user code has been entered and warns that the interlock is temporarily defeated allowing the door to be opened without tripping out the laser Sounder An internal sound...
Страница 15: ...the door to be opened without tripping out the laser A continuous sound will be made by the ICS to indicate that the system is overridden A rapid pulsed sound will be made by the keypad to indicate that the door is unlocked After a few seconds the Door Unlocked output will cease so that when the door closes it will become locked After a few more seconds the override will cease If the door is still...
Страница 16: ...ations Operating Voltage 24VDC Current Consumption 25mA standby 150mA activated Size 160mm wide X 108mm high X 38 5mm deep Weight 200g All figures quoted are approximate Lasermet reserve the right to alter specifications without prior notice 10 Warranty Lasermet provide a 12 month warranty for defects in materials and manufacture from the date of installation or delivery Installations completed by...
Страница 17: ...ovide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website www laserme...