background image

ENGLISH

15

AUTOMATIC ENGINE STOP

: 20" after the ignition is switched OFF, PASSIVE ENGINE

immobilisation becomes effective. Within 20" you can reset the time turning the ignition key

ON. When the functions are activated, the LED is constantly ON and it is not possible to start

the engine. To cancel the passive engine immobilisation turn ignition key ON and push

central button.

This function can be excluded to set the dip-switch n°4 in ON position (see dip switch coding table)

ANTI-CODE GRABBING WITH VARIABLE CODE ENCRYPTION

Today's criminals are shifting from code scanning to a new, much more efficient method of

electronic thievery: "code-grabbing."

When you use a car alarm remote control, it transmits a digital code to your alarm. A thief

with a code-grabber can record that code right off the air from hundreds of feet away, then

play it back when you're gone to disarm the alarm and unlock the doors.

Within seconds, your car is just another theft statistic. Fortunately, LASERLINE Anti-Code

Grabbing randomly changes the transmitted code every time you press any of the remote

control buttons. The system's microprocessor randomly generates each code. The remote

control NEVER sends the same code twice, and the system control unit NEVER accepts the

same code twice. That makes code-grabbing utterly useless against LASERLINE alarm

systems.

SELF CODING REMOTE HANDSETS

In case you loose a remote or need to code a new one your installer will be able to quickly

re-code and replace it in the following way:

l )

Ensure alarm is disarmed with the original remote handset.

2)

Turn ignition to on position.

3)

Open bonnet and remove access plate on rear of siren.

4)

Move DIP switch No. 1 to ON position. The LED on the dashboard will now light on

constantly.

5)

Within 30 seconds of constant LED illumination, press arm/disarm button on the new

remote until facia LED 'blinks'. New remote is now coded.

6)

 Again within 30 seconds code original remote as above (5).

7)

Reposition DIP switch No. 1 to its original position and refit access plate on rear of

siren.

8)

Turn off ignition and test remote operation.

You can add a maximum of 4 remotes

ULTRASONIC EXCLUSION THROUGH REMOTE CONTROL

- Open the driver side door and turn the ignition key ON.

- Push the button n° 1 on the remote handset.

The LED will flash once. This means that the ULTRASONIC function has been excluded. Re-

establishment will happen automatically on switching the ignition key ON.

ULTRASONIC AND WINDOW CLOUSURE EXCLUSION

- Open the driver side door and turn the ignition key ON.

- Push the button n° 2 (panic) on the remote handset.

The LED will flash twice. This means that the ULTRASONIC AND WINDOW closure have been

excluded. The re-establishment will happen automatically on switching the ignition key ON.

ULTRASONICS AND WINDOWS CLOSER EXCLUSION (only 989EES)

Arm the alarm by remote button n° 1 and within 30" depress button n°2 . Exclusion of ultrasonics and

windows closer will be signalled by 1 flash of indicator lights and 1 acoustic signal.

Functions will be automatically restored when alarm will be disarmed.

SIREN EXCLUSION THROUGH REMOTE CONTROL (only 989EES)

Turn the ignition key ON.

Push the button n° 2 on the remote handset (see fig 1).

The red LED will flash once. This means that the SIREN function has been excluded.

These functions will be automatically restored when alarm will be disarmed.

is 989E ita-ing.pm6

05/03/98, 16.42

15

Содержание 974E

Страница 1: ...ENGLISH 11 FITTING INSTRUCTION COMPACT ALARM CAR ALARMS SYSTEMS 989E 988E 989EES with siren exclusion 975E 974E without ultrasonic is 989E ita ing pm6 05 03 98 16 42 11...

Страница 2: ...OTICE Route wires as far as possible from interference sources high tension coil spark plug wires Fix ultrasonic sensors AT THE TOP of the right and left A pillars as far as possible from ventilation...

Страница 3: ...esn t happen increase the sensitivity and repeat the test Do not set too high as false alarm may result clockwise maximum sensitivity anti clockwise minimum sensitivity anti clockwise until the end se...

Страница 4: ...he same detector ULTRA SONICS SENSOR PUSH BUTTONS after the third cicle of siren sound that detector is excluded but it is not possible to start car engine SECURITY KEY inOFFpositionitexcludesalltheal...

Страница 5: ...position 3 Open bonnet and remove access plate on rear of siren 4 Move DIP switch No 1 to ON position The LED on the dashboard will now light on constantly 5 Within 30 seconds of constant LED illumina...

Страница 6: ...e concerning the Electromagnetic Compatibility EMC and the EEC 95 56 directive concerning protection device against unauthorised use of motorvehicle and ETS norms applied in this case Dip switch n Pos...

Страница 7: ...O NOT LEAVE DISCONNECTED THIS WIRE SAFETY SWITCH POSITIVE OUTPUT DURING THE ALARM 3 A max 12V WINDOWS CLOSER ART 824 811 828 POSITIVE BATTERY HAZARD BROWN YELLOW YELLOW CENTRALLOCKING BLUE AERIAL WHIT...

Страница 8: ...BLACK AND RED BLACK WIRES DIP SWITCH NO 6 OFF 1 SECOND PULSE DIP SWITCH NO 6 ON 3 SECONDS PULSE DIP SWITCH NO 5 ON 25 SECONDS PULSE lock only DO NOT USE LIGHT BLUE BLACK AND RED BLACK WIRES DIAGRAM 2...

Страница 9: ...CTIONS CUT DOOR PUMP GREEN BLACK GREY BLACK BROW BLACK YELLOW BLACK ALARM SYSTEM BLUE BLACK RED BLACK LINK POSITIVE 12V GROUND DIP SWITCH NO 6 ON 3 SECONDS DIP SWITCH NO 5 OFF 3 SECONDS DIP SWITCH NO...

Страница 10: ...connect to ground GREEN BLACK YELLOW BLACK connect to a fused positive supply GREY BLACK connect to the blue wire of the central locking motor BROWN BLACK connect to the red wire of the central lockin...