background image

                                

 

 
 
 
 
 

TLAserX30 / X60 / X120

 

 

Laser Scan Micrometers

 

(130 / 160 / 1120 / 230 / 260 / 2120) 

 

Operator’s Manual 

 

April 2010 

 

 

 

                                               
 

                                                                   

            

           

  

 

                                                                                    

          

 
 
 

LaserLinc, Inc. 

777 Zapata Drive 

Fairborn, Ohio 45324 

Telephone: 937.318.2440 

Fax: 937.318.2445

Содержание TLAser230

Страница 1: ...TLAserX30 X60 X120 Laser Scan Micrometers 130 160 1120 230 260 2120 Operator s Manual April 2010 LaserLinc Inc 777 Zapata Drive Fairborn Ohio 45324 Telephone 937 318 2440 Fax 937 318 2445...

Страница 2: ...r hardware and software included with your system have been sold to you subject to the limited warranties set forth in the warranty section set forth in your quote you were issued before purchase and...

Страница 3: ...ng TLAser130 160 2120 5 CABLING 130 160 1120 6 Typical Connectors 130 160 1120 6 TLASER230 260 2120 LASER MICROMETER 7 Specifications 230 260 2120 7 Mounting TLAser230 260 2120 7 CABLING 230 260 2120...

Страница 4: ...o a photocell generating an analog voltage When an object is placed in the measurement field it obstructs the laser beam When the beam is obstructed the photocell output voltage is at its lowest level...

Страница 5: ...apter J on laser products as stipulated by the U S Department of Health and Human Services The LaserLinc Inc products shown here correspond to the category CLASS II LASER PRODUCT in the regulation The...

Страница 6: ...scanner Specifications 130 160 1120 Mounting TLAser130 160 2120 Mounting Hole Drawings http www laserlinc com gauge_info LaserLinc TLAser130_mount pdf http public laserlinc com info 160s 160s_mounting...

Страница 7: ...The connection is via BNC connector For a discussion of the waveforms see FAQ and Troubleshooting below The AIR PORT is not applicable on the 130 160 1120 A separated air purge is available The air pu...

Страница 8: ...ble red laser diode wavelength 670 NM Optional air purges ensure reliable operation in harsh environments other accessories include roller guides stands and calibration fixtures Mounting TLAser230 260...

Страница 9: ...The connection is via BNC connector For a discussion of the waveforms see FAQ and Troubleshooting below The AIR PORT is not applicable on the 130 160 1120 A separated air purge is available The air pu...

Страница 10: ...DAMP not DRIPPING 4 Wipe each window once from side to side Do NOT scrub Do not wipe from top to bottom 5 Use a new swab or wipe for each window 6 If Windex is used a dry swab or wipe will be necessa...

Страница 11: ...heck for any additional fibers in the scan field Check each axis via the test port for correct waveform Problem Total Vu measurement reports No Scan Possible Causes 1 The scanner is not powered Check...

Отзывы: