PLMNL0252 REV. B Effective Date: 10/16/17
40
FiberCUT
®
HR Operation Manual
6 Specifications
CUTTING HEAD
Power Rating ............................................................................................................................ up to 12 kW
Fiber Input Adapter (Others Available On Request) .............................................................. QBH (HLC-8)
Focusing Optic (Nominal Focal Length) ........................................................................................... 200 mm
Collimating Optic (Nominal Focal Length) ...................................................................................... 150 mm
Clear Aperture ................................................................................................................................... 40 mm
Nozzle Tip .............................................................................................. Various Shapes and Orifice Sizes
Assist Gas Pressure .................................................................................................. up to 25 Bar (375 psi)
Purge Gas .......................................................................................... 0.5 to 0.7 Bar (7.0
– 10.0 psi) at inlet
Tip Cooling Pressure ........................................................................................... 2.0
– 3.5 Bar (30 – 50 psi)
Air Blast Pressure ............................................................................................... 2.0
– 3.5 Bar (30 – 50 psi)
Water ................................................................................................................ 5.0 Bar Max (72.5 psi max)
Weight ................................................................................................................................ 6.6 kg (14.5 lbs)
Focal Point to Nozzle Adjustment ................................................... Approximately -12.5 mm to +12.5 mm
HEIGHT SENSOR
Standoff Range ............................................................................................................... 0.2 mm to 8.0 mm
Single Point Calibration ..................................................................................................................... 12 mm
Response Time .............................................................................................................................. <1 msec
Temperature Stability ......................................................................... ±5% of Standoff Setting, 0° to 45° C
Output ..................................................................................................................................... 0-10 V Analog
Specifications are subject to change without notice.