background image

5

4.0  OPERATION

4.1  Before Using the Pump:

1.  Check all system fittings and connections to be sure 

they are tight and leak free.

2.  Check oil level in reservoir before operating pump. 

Refer to instructions in Section 5.1.

  CAUTION

 

Never add extensions to pump handle. 

Extensions cause unstable pump operation.

  WARNING  

Always keep your body to the side of the 

pump, away from the line of force of the handle.

Note:

 To reduce handle effort at high pressure, take short 

strokes. Maximum leverage is obtained in the last 5° of 

stroke.

Note:

 When operating a non-vented pump in the vertical 

position, the hose end must be pointed down, or the pump 

will pick up air and will not build pressure properly.

4.2   Using Two-Speed Pumps  

(Models W20307, W20807, W21807, W22607, 

X22607, W24507, X24507, W26507 and X26507)

These pumps provide 2-stage flow. Under no-load, the 

pump operates in the high flow first stage for rapid advance. 

When the load is contacted, the pump automatically 

transfers over to the second stage for building pressure.

Note:

 Models W22607, X22607, W24507, X24507, W26507 

and X26507: when pump pressure reaches approximately 

40 bar, you must momentarily stop pumping and raise the 

handle to shift to the high pressure stage. After the pump 

shifts, pumping will require less effort.

4.3   Single-Acting Applications with Release Valve  

(Models W10607, W11407, W20307, W20807, 

W21807, W22607 and W24507)

1.  Close release valve by turning clockwise, as shown in 

Figure 1.

Figure 1

  CAUTION  

Close release valve - 

HAND TIGHT ONLY

Using tools on release valve can damage it and cause the 

pump to malfunction.
2.  Operate pump handle to deliver hydraulic power to 

system. Pressure will be maintained until release valve 

is opened.

3.  Open release valve (turn counter-clockwise) to release 

pressure, allowing oil to flow back to the reservoir. 

Slowly open release valve to release the pressure and 

control the flow of oil back to the reservoir.

Note:

 The amount that the release valve is opened controls 

the speed of the oil returning to the pump and the retract 

speed of the cylinders lowering the load.

4.4    Single-Acting Applications with 3-Way, 2 Position 

Manual Valve (Model W26507)

1.  Shift the valve lever to the 

advance

 position. See 

Figure 2, position 2.

     

 

 

Figure 2

2

1

2

1

A

A

Retract

Advance

Valve Positions - Model W26507

2.  Operate pump handle to deliver hydraulic power to the 

system. Pressure will be maintained until the valve is 

shifted.

3.  Slowly shift the valve lever to the 

retract 

position to 

release pressure and control the flow of oil back to the 

reservoir. See Figure 2, position 1.
The amount that the valve is opened controls the 

speed of oil returning to the reservoir and the retract 

speed of the cylinder(s) lowering the load.

Note:

 Model W26507 is equipped with a directional control 

valve. Inline system check valves are recommended for 

controlling cylinder movement under load with this pump 

model.

Содержание W Series

Страница 1: ...t to LARZEP S A or the authorized dealer which sold you the hydraulic equipment LARZEP S A will repair or replace the faulty equipment whichever is deemed most appropriate LARZEP S A shall not be held liable for any consequential damages or losses which may occur as a result of faulty equipment RECEIVING INSTRUCTIONS Important Make sure to inspect all of the components for shipping damage If damag...

Страница 2: ...anical load holding Cylinders without these features should never be used as a load holding device After the load has been raised or lowered it must always be blocked mechanically WARNING USE ONLY RIGID PIECES TO HOLD LOADS Carefully select steel or wood blocks that are capable of supporting the load Never use a hydraulic cylinder as a shim or spacer in any lifting or pressing application WARNING ...

Страница 3: ... 46 0 4 0 2600 14 5 W24507 2 28 700 46 0 4 0 4450 18 1 X24507 2 28 700 46 0 4 0 4450 19 5 W26507 2 28 700 126 0 4 9 6500 20 0 X26507 2 28 700 126 0 4 9 6500 20 8 Note Models beginning with W are for use with single acting cylinders and tools Models beginning with X are for use with double acting cylinders and tools 2 2 Hand Pump Hydraulic Connections Outlet Port Outlet Ports Release Screw Assembly...

Страница 4: ...retract port b For double acting cylinders use two hoses Connect the first hose from the pump advance port A to the cylinder advance port Connect the second hose from the pump retract port B to the cylinder retract port WARNING One or more shipping plugs are used to prevent residual oil from leaking out of port s during shipment Do not operate pump with the shipping plug s installed Oil may be exp...

Страница 5: ...7 W20307 W20807 W21807 W22607 and W24507 1 Close release valve by turning clockwise as shown in Figure 1 Figure 1 CAUTION Close release valve HAND TIGHT ONLY Using tools on release valve can damage it and cause the pump to malfunction 2 Operate pump handle to deliver hydraulic power to system Pressure will be maintained until release valve is opened 3 Open release valve turn counter clockwise to r...

Страница 6: ...oval Removing air from the hydraulic system will help the cylinder to advance and retract smoothly Refer to the procedure in the following steps 1 On pumps with non vented reservoirs loosen the oil fill plug On pumps with vented reservoirs loosen the vent screw 2 Single acting pump models Close the release valve or move the control valve lever to the advance position Double acting pump models Move...

Страница 7: ...illed If a non vented reservoir is completely filled a vacuum will form preventing proper operation of the pump 5 3 Filling Vented Reservoirs models W24507 X24507 W26507 and X26507 Vented reservoirs can be filled up to the bottom of the oil fill hole However it is recommended to leave a small air gap to allow optimum functioning of the venting system Models W26507 and X26507 must be filled to with...

Страница 8: ...ording to the maintenance instructions Close the release valve Check that all couplers are fully tightened Do not attempt to lift more than rated tonnage Remove air according to instructions Check for damage to cylinder Have cylinder serviced by a qualified hydraulic technician Cylinder advances but does not hold pressure Leaking connection Leaking seals Internal leakage in pump Check that all con...

Страница 9: ... S A o al distribuidor autorizado que le vendió el equipo LARZEP S A reparará o reemplazará el equipo defectuoso según se juzgue oportuno LARZEP S A no será responsable de ninguna pérdida o daño que pueda ocurrir como resultado de un equipo defectuoso INSTRUCCIONES DE RECEPCIÓN Importante Asegúrese de inspeccionar todos los componentes para comprobar si están dañados a causa del transporte Si encu...

Страница 10: ...cánica de la carga Cilindros sin estas características nunca deberían usarse como un dispositivo de retención de cargas Después de que la carga se haya subido o bajado debe bloquearse siempre mecánicamente ADVERTENCIA USE SOLO PIEZAS RÍGIDAS PARA SOSTENER CARGAS Seleccione cuidadosamente bloques de acero o de madera capaces de soportar la carga Nunca use un cilindro hidráulico como calza o separad...

Страница 11: ... 46 0 4 0 4450 18 1 X24507 2 28 700 46 0 4 0 4450 19 5 W26507 2 28 700 126 0 4 9 6500 20 0 X26507 2 28 700 126 0 4 9 6500 20 8 Observación Los modelos que comienzan con W son para uso con cilindros y herramientas de simple efecto Los modelos que comienzan con X son para uso con cilindros y herramientas de doble efecto 2 2 Conexiones hidráulicas de la bomba manual Puerto de salida Puertos de salida...

Страница 12: ...ntilación o sin ventilación Consulte la tabla siguiente para determinar el tipo de depósito en la bomba 3 3 Purgar el depósito modelos W24507 X24507 W26507 y X26507 Para que pueda funcionar la bomba debe abrirse la ventilación Si la ventilación está bloqueado o cerrado la bomba no funcionará correctamente o no será operativa Gire el tornillo de purga en sentido antihorario para abrir ventilación P...

Страница 13: ...W21807 W22607 y W24507 1 Cierre la válvula de descarga girándola en el sentido horario como se muestra en la Figura 1 Figura 1 PRECAUCIÓN Cierre la válvula de descarga SÓLO A MANO El uso de herramientas en la válvula de descarga pueden dañarla y provocar un mal funcionamiento de la bomba 2 Accione la palanca de la bomba para aplicar potencia hidráulica al sistema La presión se mantendrá hasta que ...

Страница 14: ...ire del sistema hidráulico ayudará a que el cilindro avance se retraiga suavemente En los siguientes pasos se describe el procedimiento 1 En las bombas con depósitos sin ventilación afloje el tapón de llenado de aceite En las bombas con depósitos con ventilación afloje el tornillo de purga 2 Modelos de bomba de simple efecto cierre la válvula de descarga o mueva la palanca de la válvula de control...

Страница 15: ...ma un vacío impidiendo el funcionamiento correcto de la bomba 5 3 Llenar depósitos con ventilación modelos W24507 X24507 W26507 y X26507 Los depósitos con ventilación pueden llenarse hasta la parte inferior del orificio de llenado de aceite Sin embargo es recomendable dejar un pequeño espacio de aire para permitir un funcionamiento óptimo del sistema de purga Los modelos W26507 y X26507 debe llena...

Страница 16: ... de descarga Compruebe que todos los enchufes estén completamente apretados No intente levantar más tonelaje del nominal Elimine el aire según las instrucciones Compruebe daños en el cilindro Haga revisar el cilindro por un técnico hidráulico cualificado El cilindro avanza pero no retiene la presión Conexión con fugas Fugas en las juntas Fugas internas en la bomba Asegúrese de que las conexiones e...

Отзывы: