CHAPTER 4 

OPERATION 

4-5 

 

DT-203P, DT-105P and DT-110P display series 

 

4.5

 

Inputs characteristics. 

- D0 Data inputs. Bit 1 
- D1 Data inputs. Bit 2 
- D2 Data inputs. Bit 4 
- D3 Data inputs. Bit 8 
- D4 Data inputs. Bit 16 
- D5 Data inputs. Bit 32 
- D6 Data inputs. Bit 64 
- D7 Data inputs. Bit 128 
- D8 Data inputs. Bit 256 
- CT1-CT2 Select specific functions. 
- SM Strobe Messages. Impulse (10ms) activated or deactivated a message. 

- SV Strobe Variables. Impulse (10ms), variable validate. 
- SR Set/Reset. Auxiliary signal for activated or deactivated. 
 
 

4.6

 

How to send messages to the display 

There are three ways to send a message once the displayed is programmed: 
- Displaying only one message 
- Displaying all messages in EEPROM 

The number of lines of a message has nothing to do with the way a message is sent 
because  the  corresponding  lines  and  texts  are  defined  by  the  message  edited  in 
TED program. 

 
All the following specifications have nothing to do with the number of lines of the display 
 

4.7

 

General specifications for working with the variables. 

To display variables, there are some conditions to consider: 
-The  variables  characters  have  to  be  previously  programmed  from  TED  program  to  the 

message. 

- The message has to be activated and it has to be the last activated. When a message is not 

the last one activated, it has to be activated again. The fact of activating one message which has been 
previously activated does not display this message two times. 

- The internal position counter of the variables has to be loaded with (0-15) value, which says 

the position of the variable. 

This  method  allows  modifying  a  variable  value  or  group  of  variables  value  without  changing 

the  other  variables.  Every  time  a  variable  character  is  sent,  the  position  counter  increases 
automatically to the following position. The variable direction of every character can be sent although it 
is easier to load the direction value of the first variable and to let the counter increase the directions by 
itself. 

 

 

 

Содержание DT-203P Series

Страница 1: ...10939K12L OPERATION MANUAL FOR DISPLAYS OF SERIES DT 203P DT 105P AND DT 110P...

Страница 2: ...ay and PC computer using RS 232 3 2 3 5 Characteristics of temperature humidity probe Option 3 3 3 6 Wiring of temperature humidity probe Option 3 3 3 7 Connecting displays with protection IP54 or IP6...

Страница 3: ...eading up to 15 meters 50mm height for DT 105 which allows a reading up to 25 meters 100mm height for DT 110 which allows a reading up to 50 meters They are manufactured in one or two sides of display...

Страница 4: ...2 Display 7x5 Dot matrix of 50mm high Red Led colour Visibility 25 meters Parameter memory Eeprom Watch calendar Second Minute Hour Day Month Year Control inputs 12 to 24Vcc PNP NPN or contact Serial...

Страница 5: ...136 DT 105 2D 26 13 5 92 354 DT 110 3D 13 27 72 244 DT 105 2S 33 13 5 60 220 DT 110 3S 20 27 5 55 200 DT 105 2D 33 16 115 442 DT 110 3D 20 38 5 105 376 DT 105 2S 40 15 5 72 266 DT 110 3S 26 35 5 72 26...

Страница 6: ...D 20 985 648 X 112 424 X 968 X O O DT 105 7S D 20 985 754 377 72 610 305 968 O O O DT 105 8S D 20 985 860 430 72 716 358 968 O O O DT 110 1S D 6 666 177 82 5 X X X 649 O X X DT 110 1S D 13 1276 177 82...

Страница 7: ...P display series Measures in millimetres X Not valid for these model P1 P2 and P3 Anchorage point Used O Not used X Anchorage holes position on the wall See valid point P1 P2 o P3 on the table in the...

Страница 8: ...Displays DT 203 DT 105 and DT 110 should not be installed in places with illumination level higher than 1000 lux Neither should the display be placed in direct sunlight as visibility would be lost Dis...

Страница 9: ...ay 3 3 Serial line connection All displays with serial line option may use RS232 and RS485 serial lines Both use the same connector located at the bottom of display The displays use DB9 connector 1 2...

Страница 10: ...or IP65 protection the following instructions must be followed 1 The connectors must be used with the cover placed 2 The covers must be the ones supplied with the display which are provided of gland...

Страница 11: ...rammed message on the memory 4 2 Message programming In order to program the messages in the memory Eeprom a PC and the TDLWin Version later than 1 5 specifically designed to program the messages into...

Страница 12: ...4 3 2 Exit modify parameters In order to exit the sequence for modifying parameters parameter EXIT must be selected then press 4 3 3 Function of each parameter 4 3 3 1 Parameter LANGUAGE or LA The la...

Страница 13: ...ightness while level 8 is the maximum brightness 4 3 3 12 Parameter POSITION OF THE CONNECTORS This allows the user to select the orientation of the text depending on the position of the connectors to...

Страница 14: ...From this code on the characters are not in flashing method anymore External variable It saves one character from the text to enter an external variable it takes two characters In message memory one e...

Страница 15: ...ing specifications have nothing to do with the number of lines of the display 4 7 General specifications for working with the variables To display variables there are some conditions to consider The v...

Страница 16: ...ctivated CT1 CT2 SM 0 Deactivated D0 D7 ASCII code D8 Irrelevant SV 1 Pulse activated 10 mseg As BCD forms part of ASCII code variables can be sent in BCD code with D4 and D5 inputs They have to be ac...

Страница 17: ...o consecutive operations are needed to send it The 8 high bits with the sign must be sent and then the 8 low bits with the sign To send the 8 high bits Set SR CT1 1 Activated CT2 SM 0 Deactivated D0 D...

Страница 18: ...mber of messages to be sent is 2048 messages by using 11 PLC outputs The number of PLC outputs required depends on the number of messages wished to be sent For example to send 52 messages it is requir...

Страница 19: ...can be displayed simultaneously in displaying messages in EEPROM mode which are loaded in an internal buffer of RAM memory If there are more than ten messages no more messages will be accepted until s...

Страница 20: ...ivate again the message with the new selected mode Example If message n 3 n 22 and n 1 are activated in this order in a option message n 3 will be displayed In order to display all the messages any of...

Страница 21: ...ting this command all messages are posted with the configured brightness Modify the time between messages Between 1 and 99 seconds After executing this command all posts use this time 4 8 3 Protocol 1...

Страница 22: ...ioned product complies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment Directive EMC 2014 30 UE Electromagn...

Отзывы: