background image

1660K023G 

 

Page 3 of 30 

DC-41SRTHO characteristics. 

Power supply

 ............................................... 100 VAC a 240 VAC   50/60Hz 

Consumption

 ................................................ 35VA 

Consumption at minimum brightness

 ....... 13,2VA. 

Display 

Time ............................................................... 4 digits  7segments 100mm height. Format HH:MM. Red LED. 
Temperature .................................................. 3 digits  7segments 100mm height. Red LED. 
Humidity ......................................................... 2 digits  7segments 100mm height. Red LED. 
CO

2

 measure ................................................. 4 digits  7segments 57mm height. Red LED. 

 ....................................................................... Visibility 50 meters. (25mm in CO

2

Environmental conditions

 .......................... Operating temperature: -20 to 60ºC. 

 ....................................................................... Storage temperature: -20ºC to 70ºC 
 ....................................................................... Relative humidity:  5-95% non condensation. 
 ....................................................................... Maximum environmental lighting: 1000 lux. 
 ....................................................................... Protection IP 41. 

Weight

 ........................................................... .4,5 Kg. 

Temperature precision

 ................................ ±0,5°C typ ±2,5 MAX 

Temperature resolution

 .............................. 0,1ºC 

Humidity precision

 ...................................... ±4,5% between 20% and 80% 

Humidity resolution

 ..................................... 1% 

CO

2

 precision

 ............................................... ±30ppm or 3% of the measurement between 400 and 1250ppm 

CO

resolution

 .............................................. 1ppm 

Sensor cable length

..................................... 2 meters. 

 

Timed power-up of the display 

This display operates in two operation modes: full-operative mode and power-saving mode. In power-

saving mode the display does not show the time in order to save energy when the display is not needed. If the 
power-saving  function  is  not  needed  and  the  display  should  always  powered  up,  the  both  power-up  and 
power-down times must be the same. 

Parameters of the display 

There  are  three  keys  on  the  back  side  of  the  display.  These  keys  are  used  to  access  and  navigate 

through the menu of the display. The identification of the keys is 

 
   

 

 

 

Advance key. Access parameter/switch digits. 

  
  

 

Enter key. Validate parameter. 

  
  

Increase key. Increase the value of the selected digit. 

  
 

Error displaying 

The only  error that can appear  is a temperature/humidity error. The text  displayed  in  this case is E02  in the 
display. If this occurs, reboot the display.  

 

 

Содержание DC-41SRTHO

Страница 1: ...er up This is done using one of the parameters of the display see GPS option in this manual If the display includes option NE Ethernet connectivity this display hosts a web site where the user can see the status of the display and configure it This function allows the display to be used as a server for other displays to synchronize the hour through the Ethernet as well as updating its time and dat...

Страница 2: ...ove the methacrylate cover Place the 4 supplied plugs at the distance showed in the drawing Place the 2 upper screws leaving their head outside for 4 mm Hang the display using the upper side zig zag Place the lower screws Tighten all the screws Replace the methacrylate cover Powering the display Power supply must be from 100VAC to 240VAC 50 60 Hz You must use a Schuko type plug that has grounded t...

Страница 3: ...ppm or 3 of the measurement between 400 and 1250ppm CO2 resolution 1ppm Sensor cable length 2 meters Timed power up of the display This display operates in two operation modes full operative mode and power saving mode In power saving mode the display does not show the time in order to save energy when the display is not needed If the power saving function is not needed and the display should alway...

Страница 4: ...guration easy for the user when changing a parameter a point is turned on This point changes depending on the sub parameter if it exists the user is in 8 8 88 88 88 8 8 88 88 8 8 ENTER ENTER ENTER Parameters are detailed below Parameter 1 Date configuration This parameter configures de date as well as the wintertime summertime automatic switchover configuration When entering this parameter the day...

Страница 5: ...ay without Ethernet connection selecting SNTP sync will have no effect Options are 0 Do not sync 1 Sync with another display through Ethernet 2 Sync through SNTP 3 Sync with another display through RS 485 4 Sync through GPS Parameter 5 Display power up time This parameter configures the time the display changes form power save mode to full operative mode When accessing in this parameter the hour t...

Страница 6: ...ds 8 bits Odd 1 17 9600 Bauds 8 bits Odd 1 18 19200 Bauds 8 bits Odd 1 19 4800 Bauds 7 bits No parity 2 20 9600 Bauds 7 bits No parity 2 21 19200 Bauds 7 bits No parity 2 22 4800 Bauds 8 bits No parity 2 23 9600 Bauds 8 bits No parity 2 24 19200 Bauds 8 bits No parity 2 25 4800 Bauds 7 bits Even 2 26 9600 Bauds 7 bits Even 2 27 19200 Bauds 7 bits Even 2 28 4800 Bauds 8 bits Even 2 29 9600 Bauds 8 ...

Страница 7: ...Displays that include GPS sync with the GPS standard signal This allows a better time sync without Ethernet connectivity GPS antenna includes a magnet that can be fixed to a ferric surface This antenna must be placed close to a window or in a place with thin roof The most hidden the antenna is the longer will take to get the GPS signal GPS can spend up to half an hour to fix the signal if the ante...

Страница 8: ... range of you LAN it is recommended to use the PC program Display Discoverer downloadable from the web www lartet com In this program the displays connected to the LAN are displayed as well as their IP addresses their MAC addresses all MAC are 00 04 A3 xx xx xx and its name The default name of the display is its serial number This name can be changed in the Ethernet tab of the web server of the di...

Страница 9: ...1660K023G Page 9 of 30 Tip the new IP and click OK There will appear a message in the main window with the message sent to the display ...

Страница 10: ...1660K023G Page 10 of 30 After some seconds click the Refresh button The display appears with the new IP Click the display IP to open a new tab in the browser The main page of the web server is shown ...

Страница 11: ...a difficult access point The web page can be accessed remotely if the router is correctly redirected See Annex 2 View the web page remotely for more information The main page shows the same date and time of the display as well as the temperature the humidity the CO2 concentration and the GPS signal quality if the option is included and the display IP This main page is for the user to control the s...

Страница 12: ...n in the field The second tab allows configuring the network parameters of the display including the IP address DNS etc The display can use DHCP to get these parameters on its own The name of the display can be changed according to the needs of the user This name is used to identify and access the display throw web browser typing the name in the URL In case of failure or errors reset the display b...

Страница 13: ...actions parameters seen from the webpage the user must configure Other parameters don t care Networks with one display One display Ethernet network Ethernet network Time and date introduction by user if necessary Configure net parameters Sync no One display with GPS Ethernet network Ethernet network Review parameter A GPS signal Sync GPS Review parameter A from the web ...

Страница 14: ... Both are configured the same way Ethernet network Ethernet network Ethernet network Ethernet network SNTP server Configure net parameters Sync SNTP Write the server addres in the field SNTP server Configure net parameters Sync SNTP Write the server addres in the field ...

Страница 15: ...thers sync with the server display Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Server display Configure net parameters Sync GPS DHCP no Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field ...

Страница 16: ...SNTP server and serves the time to the other displays Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Server display Configure net parameters Sync SNTP Write the server addres in the field DHCP no SNTP server Client display Configure net parameters Sync Display Ethernet Write the display server addres in t...

Страница 17: ...rver o a cloud SNTP server All displays update from the SNTP server specified Ethernet network Ethernet network Configure net parameters Sync SNTP Write the server addres in the field SNTP server Configure net parameters Sync SNTP Write the server addres in the field Configure net parameters Sync SNTP Write the server addres in the field ...

Страница 18: ...0 The following frames can be sent Command Code Data End of block Display time request P H Display temperature request P T Display humidity request P U Displayed CO2 request P C Time programming F H Display time request Frame This frame only includes the code This does not send any data Code End of block ACII P H Hexa 50h 48h Response frame Code Data End of block Code Day Month Year Space Hour Min...

Страница 19: ...CII R T T T T Hexa 52h 54h 2Eh Example Temperature 17 2ºC Code Data End of block ASCII R T 1 7 2 Hexa 52h 54h 31h 37h 2Eh 32h Display humidity request Frame This frame only includes the code This does not send any data Code End of block ACII P U Hexa 50h 54h Response frame Code Data End of block ASCII R U H H Hexa 52h 54h Example Humidity 60 Code Data End of block ASCII R U 6 0 Hexa 52h 54h 36h 30...

Страница 20: ... CO2 concentration 728ppm Code Data End of block ASCII R U 0 7 2 8 Hexa 52h 54h 30h 37h 32h 38h Time programming Frame Code Data End of block Code Day Month Year Space Hour Minute Second End of block ASCII F H DD MM AA HH MM SS Hexa 46h 48h 20h Example 13 06 00 16 05 2013 Code Data End of block Code Day Month Year Space Hour Minute Second End of block ASCII F H 16 05 13 13 16 00 Hexa 46h 48h 31h 3...

Страница 21: ...tion must be the same for all RS 485 network There are many configurations possible only with RS 485 or combining different options this displays offer The following networks are the most usual but the user can create new ones Sync through one display without more options RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server disp...

Страница 22: ...023G Page 22 of 30 Sync through a display with GPS RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server display Sync Parameter 4 2 4 GPS ...

Страница 23: ...ed to a SNTP server Ethernet network Ethernet network RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Server display Configure net parameters Sync SNTP Write the server addres in the field SNTP server Client display Sync Parameter 4 2 3 RS 485 ...

Страница 24: ...request P U Display CO2 concentration request P C Time programming F H Display time request Frame This frame only includes the code This does not send any data Code Address End of block ACII P H H L Hexa 50h 48h Example Request time from the display in address 03 Code Address End of block ACII P H 03 Hexa 50h 48h 30h 33h Response frame Code Address Data End of block Code Address Day Month Year Spa...

Страница 25: ...54h Example Request temperature from the display in address 03 Code Address End of block ACII P T 03 Hexa 50h 54h 30h 33h Response frame Code Address Data End of block ASCII R T H L T T T Hexa 52h 54h 2Eh Example Response from the frame sent in the example before Temperature 17 2ºC Code Address Data End of block ASCII R T 03 1 7 2 Hexa 52h 54h 30h 33h 31h 37h 2Eh 32h ...

Страница 26: ... Hexa 50h 54h Example Request temperature from the display in address 03 Code Address End of block ACII P U 03 Hexa 50h 54h 30h 33h Response frame Code Address Data End of block ASCII R U H L H H Hexa 52h 54h Example Response from the frame sent in the example before Humidity 60 Code Address Data End of block ASCII R U 03 6 0 Hexa 52h 54h 30h 33h 36h 30h ...

Страница 27: ...esponse from the frame sent in the example before CO2 concentration 728ppm Code Address Data End of block ASCII R U 03 0 7 2 8 Hexa 52h 54h 30h 33h 30h 37h 32h 38h Time programming Frame Code Address Data End of block Code Address Day Month Year Space Hour Minute Second End of block ASCII F H H L DD MM AA HH MM SS Hexa 46h 48h 20h Example Send 13 16 00 16 05 2013 to the display at address 03 Code ...

Страница 28: ...inal Port The same port as the start port Internal Start Port The port the user enters wants to enter the display In this case the port is 80 which is the standard web page access IP address The LAN IP of the display Port redirection configuration Server name External Start Port External Final Port Protocol Internal Start Port Internal Final Port Server IP address Display 10021 10021 TCP 80 80 192...

Страница 29: ...lies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment Directive EMC 2014 30 UE Electromagnetic Compatibility Standard UNE EN 61000 6 4 Generic Emission Standard Industrial environment Standard UNE EN 61000 6 2 Generic Immunity Standard Industrial environment Directive 2011 65 CE Restriction of the use of ce...

Отзывы: